PubMed HealthSearch

PubMed · 9155707

Do HPV-negative cervical carcinomas exist?

Abstract

Based on improvements in HPV detection technology, it appears that an almost 100% HPV association is reached for cervical cancer, as demonstrated in an accompanying paper in this issue of the Journal. Factors which may explain the rare cases in which no HPV DNA is detectable include: improper sampling; disruption of HPV by integration events; the existence of still unidentified HPVs; sensitivity of the method; and the mechanism of transformation. Finally, epidemiological studies identifying HPV independent risk factors are necessary to answer the question of whether HPV independent pathways exist for cervical carcinogenesis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J M Walboomers, C J Meijer. 1997. Do HPV-negative cervical carcinomas exist?. https://doi.org/10.1002/(sici)1096-9896(199703)181%3A3%3C253%3A%3Aaid-path755%3E3.0.co%3B2-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simultaneous visual detection of multiple viral amplicons by dipstick assay.

A sensitive, simple, and instrument-independent method for the visual detection and identification of multiple nucleic acid amplicons by dipstick has been developed. This method is based on nucleic acid hybridization on the dipstick membrane and a signal amplification system to allow visual detection. With hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus type 1 (HIV-1) as model analytes, it is demonstrated that the visual dipstick test combined with multiplex reverse transcription (RT)-PCR for the amplification of viral nucleic acid provides a specific and sensitive detection method. The RT-PCR products were detected by the dipstick with an efficiency similar to that of a complex, expensive, and instrument-dependent method based on fluorogenic oligonucleotide probes. The detection limits of the dipstick combined with multiplex RT-PCR were 50, 125, and 500 IU/ml for HBV DNA, HCV RNA, and HIV-1 RNA, respectively. The dipstick assay detected with similar efficiencies amplicons derived from strains of HBV genotypes A through F, HCV genotypes 1 to 6, and HIV-1 subtypes A through H as well as CRF02 circulating recombinant forms of HIV-1. Analysis of 295 clinical samples and 19 pools of 10 plasma specimens from blood donors revealed that multiplex dipstick detection was reproducible, sensitive, and specific. The visual dipstick detection of multiple amplicons thus provides an attractive alternative to complex, instrument-dependent detection methods currently in use for nucleic acid testing. This new and sensitive method for nucleic acid detection should increase the availability of genomic screening in resource-limited settings and its applicability to near-patient testing.

DNA, Viral

Two-centre study comparing DNA preparation and PCR amplification protocols for herpes simplex virus detection in cerebrospinal fluids of patients with suspected herpes simplex encephalitis.

In a two-centre study, the routine DNA preparation and PCR amplification protocols were compared for herpes simplex virus (HSV) detection in cerebrospinal fluids (CSFs) of 43 patients with suspected herpes simplex encephalitis (HSE). The combined clinical, radiological and laboratory results indicated HSE in 6/43 (14%) patients. Discrepant PCR results between the two centres were obtained in 8 (18%) cases consisting of 5 false-positive and 3 false-negative results. Seven out of 8 (88%) discrepant results were associated with the method of CSF preparation using protease K digestion followed by heat inactivation. In contrast, CSF digestion with proteinase K followed by DNA purification on silica spin columns was better yielding discrepant PCR results in only 1 of 78 analyses (1.3%). The results point to the need for standardization and inter-laboratory quality control for routine clinical work.

DNA, Viral

Quantitative detection of hepatitis B virus DNA in two international reference plasma preparations. Eurohep Pathobiology Group.

Quantitative detection of hepatitis B virus (HBV) in serum or plasma is of significance for monitoring of therapy and establishment of the prognosis of the disease, as well as for infectivity assessment and quality control of the diagnosis. Unfortunately, various commercially available test kits for HBV DNA yielded conflicting quantitative results, with differences of up to a factor of 120. The Eurohep Pathobiology Group has established two reference samples of plasma from HBV carriers and determined as accurately as possible the number of HBV DNA molecules in these samples. Plasma donations from two single highly viremic carriers of HBV genotype A (HBV surface antigen subtype adw2) and genotype D (ayw2/3), respectively, were collected, and coded dilutions of these samples were analyzed by members of the Eurohep Pathobiology Group. Quantitative results from the seven laboratories reporting consistent results were initially divergent. Limiting dilution and nested PCR assays suffered from incomplete DNA extraction. Hybridization assays used inaccurately quantitated cloned DNA as a reference. Two hybridization assays could not be calibrated directly with cloned HBV DNA, because virion-derived DNA reacted much less efficiently. After identification and elimination of these problems, limiting-dilution assays from three laboratories and hybridization assays from two producers generated consistent and concordant results: 2.7 x 10(9) HBV DNA molecules/ml (range, 2.1 x 10(9) to 3.4 x 10(9) HBV DNA molecules/ml) in the plasma from the carrier of genotype A and 2.6 x 10(9) HBV DNA molecules/ml (range, 2.1 x 10(9) to 3.0 x 10(9) HBV DNA molecules/ml in the plasma from the carrier of genotype D. The two Eurohep reference plasma samples have already been used for the standardization of test kits and in quality control trials, and the plasma from the carrier of genotype A will probably be the basis of a World Health Organization reference sample.

DNA, Viral