PubMed Health⌕ Search

PubMed · 9163278

[S-(+)-Ketamine and circulation].

Abstract

The S-(+) isomer of ketamine has about twice the analgesic potency of the clinically used racemic mixture. Therefore, the known side effects may be reduced when one-half of the usual dose is administered. Several prospective, randomised, and double-blinded studies have been performed to assess whether the S-(+) isomer of ketamine is superior to the racemic mixture with respect to circulatory side effects. Studies in young, healthy volunteers showed that heart rate (HR) and arterial blood pressure (ABP) rise significantly after injection of 2 mg/kg ketamine racemate and 1 mg/kg S-(+) isomer without any significant difference between groups. In the study of Doenicke et al. plasma levels of adrenaline (A) were higher in the racemate group, whereas no difference was found in elevated plasma levels of noradrenaline (NA). Premedication with midazolam blunted major haemodynamic changes. The investigation of Adams et al. confirmed that HR and ABP rise significantly after injection of 2 mg/kg ketamine racemate and 1 mg/kg S-(+) isomer without any significant difference between groups. In this study, no differences were found between groups concerning elevated plasma levels of A and NA. A further study in healthy volunteers also showed comparable haemodynamic changes following i.m.injection of 1.0 mg/kg ketamine racemate or 0.5 mg/kg S-(+) isomer without any significant difference between groups. In a previous clinical study including 40 elderly patients undergoing elective orthopaedic surgery, total intravenous anaesthesia (TIVA) was performed with S-(+)-ketamine or ketamine racemate as an analgesic compound. For induction of TIVA, patients received 0.1 mg/kg midazolam and 1 mg/kg S-(+)-ketamine or 2 mg/kg racemic ketamine, respectively. Throughout surgery, a continuous infusion of 2 mg/kg per hour S-(+)-ketamine or 4 mg/kg racemic ketamine was administered. Three patients in the racemate group showed severe arterial hypertension after induction of anaesthesia and were withdrawn from the study. In both groups plasma A and NA levels as well as HR and ABP increased significantly. In our own randomised, double-blinded study, haemodynamic effects of 2 mg/kg S-(+)-ketamine and 4 mg/kg ketamine racemate, respectively, were investigated in 14 patients undergoing elective aorto-coronary bypass surgery. In both groups HR and ABP significantly increased in 3 patients, each although all patients were deeply sedated with midazolam. One patient in the S-(+)-ketamine group showed severe arterial hypertension and tachycardia after induction of anaesthesia and was withdrawn from the study. With respect to haemodynamic changes, the pharmacodynamic effects of ketamine racemate and S-(+)-ketamine are comparable. Therefore, it can be concluded that neither ketamine nor S-(+)-ketamine should be used in patients who suffer, e.g., from arterial hypertension and coronary artery disease.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Zielmann, S Kazmaier, S Schnüll, A Weyland. 1997. [S-(+)-Ketamine and circulation].. https://doi.org/10.1007/pl00002464

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of anesthesia on echocardiographic assessment of left ventricular structure and function in rats.

Echocardiography is an essential diagnostic tool for accurate noninvasive assessment of cardiac structure and function in vivo. However, the use of anesthetic agents during echocardiographic studies is associated with alterations in cardiac anatomical and functional parameters. We sought to systematically compare the effects of three commonly used anesthetic agents on echocardiographic measurements of left ventricular (LV) systolic and diastolic function, LV dimensions, and LV mass in rats. Adult male Fischer 344 rats underwent echocardiographic studies under pentobarbital (PB, 25 mg/kg i.p.) (group I, n = 25), inhaled isoflurane (ISF, 1.5%) (group II, n = 25),or ketamine/xylazine (K/X, 37 mg/kg ketamine and 7 mg/kg xylazine i.p.) (group III, n = 25) anesthesia in a cross-over design. Echocardiography was also performed in an additional group of unanesthetized conscious rats (group IV, n = 5). Postmortem studies were performed to validate echocardiographic assessment of LV dimension and mass. Rats in group I exhibited significantly higher LV ejection fraction, fractional shortening, fractional area change, velocity of circumferential fiber shortening corrected for heart rate, and heart rate as compared with groups II and III. LV end-diastolic volume, end-diastolic diameter, and cross-sectional area in diastole were significantly smaller in group I compared with groups II and III. Cardiac output was significantly lower in group III compared with groups I and II. Postmortem LV mass measurements correlated well with echocardiographic estimation of LV mass for all anesthetic agents, and the correlation was best with PB anesthesia. Limited echocardiographic data obtained in conscious rats were similar to those obtained under PB anesthesia. We conclude that compared with ISF and K/X anesthesia, PB anesthesia at a lower dose yields echocardiographic LV structural and functional data similar to those obtained in conscious rats. In addition, PB anesthesia also facilitates more accurate estimation of LV mass.

Anesthetics, General↗

A succession of anesthetic endpoints in the Drosophila brain.

General anesthetics abolish behavioral responsiveness in all animals, and in humans this is accompanied by loss of consciousness. Whether similar target mechanisms and behavioral endpoints exist across species remains controversial, although model organisms have been successfully used to study mechanisms of anesthesia. In Drosophila, a number of key mutants have been characterized as hypersensitive or resistant to general anesthetics by behavioral assays. In order to investigate general anesthesia in the Drosophila brain, local field potential (LFP) recordings were made during incremental exposures to isoflurane in wild-type and mutant flies. As in higher animals, general anesthesia in flies was found to involve a succession of distinct endpoints. At low doses, isoflurane uncoupled brain activity from ongoing movement, followed by a sudden attenuation in neural correlates of perception. Average LFP activity in the brain was more gradually attenuated with higher doses, followed by loss of movement behavior. Among mutants, a strong correspondence was found between behavioral and LFP sensitivities, thereby suggesting that LFP phenotypes are proximal to the anesthetic's mechanism of action. Finally, genetic and pharmacological analysis revealed that anesthetic sensitivities in the fly brain are, like other arousal states, influenced by dopaminergic activity. These results suggest that volatile anesthetics such as isoflurane may target the same processes that sustain wakefulness and attention in the brain. LFP correlates of general anesthesia in Drosophila provide a powerful new approach to uncovering the nature of these processes.

Anesthetics, General↗

Can general anaesthesia be used for the Paralytic Shellfish Poison bioassay?

The current method for Paralytic Shellfish Poisoning (PSP) testing in shellfish is based on the mouse bioassay (MBA), which involves injecting shellfish extract into a conscious mouse, and then converting its time to death into PSP toxicity using Sommer's table. To improve animal welfare, the present study investigated the use of anaesthesia. A saxitoxin (STX) calibration study was conducted where known amounts of STX were injected into both unanaesthetised and anaesthetised mice. Death time was approximately doubled when mice were anaesthetised. Both unanaesthetised and anaesthetised animals showed a linear relationship between the inverse death time and log(STX). Based on these data, new calibration curves were developed. This study revealed that the current method employing Sommer's table underestimates toxicity by up to 50% for higher toxin levels. Subsequently, shellfish samples were tested on both unanaesthetised and anaesthetised mice. Using the new calibration curves, the numbers of samples exceeding the field closure limit were similar for unanaesthetised and anaesthetised mice, and were nearly two-fold higher than those obtained with the current method. The studies showed that the bioassay gives variable results for both unanaesthetised and anaesthetised animals. Anaesthesia forms a viable and more ethical alternative to the current bioassay, at least in the short term. A practical summary on how to conduct this method is given.

Anesthetics, General↗