PubMed HealthSearch

PubMed · 9170971

[Medical practice-supporting system in pulmonary function testing].

Abstract

A pulmonary function testing system which automates measurement, storage and reporting as much possible has been functioning in Mitsui Memorial Hospital since 1992. Data obtained from four measurement apparatus are transferred to the central microcomputer by a local area network (LAN). To facilitate automatic interpretation, we developed a knowledge-based system using 87 production rules called 'PADRES', because the knowledge-based system had the following advantages over other systems; (1) The expression of knowledge is understandable and new pieces of knowledge can be easily added, (2) the process of reasoning can be clearly shown, and (3) the accumulation of many instances of data is not required. Using 'PADRES', it takes 2.6 seconds to interpret one set of data on average. Our system performs about 5,000 routine pulmonary function tests per year without faults. Because the program for interpretation is a separate module written in C language, it is readily portable to other operating systems (OS), although its original target was OS-9, a multitask operating system for microcomputers. In conclusion, the application of a knowledge-based system for microcomputers in the pulmonary function test laboratory was considered successful.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Kino. 1997. [Medical practice-supporting system in pulmonary function testing].. https://pubmed.ncbi.nlm.nih.gov/9170971/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Problem list in computer-based patient records].

Computer-based clinical information systems are capable of effectively processing even large amounts of patient-related data. However, physicians depend on rapid access to summarized, clearly laid out data on the computer screen to inform themselves about a patient's current clinical situation. In introducing a clinical workplace system, we therefore transformed the problem list-which for decades has been successfully used in clinical information management-into an electronic equivalent and integrated it into the medical record. The table contains a concise overview of diagnoses and problems as well as related findings. Graphical information can also be integrated into the table, and an additional space is provided for a summary of planned examinations or interventions. The digital form of the problem list makes it possible to use the entire list or selected text elements for generating medical documents. Diagnostic terms for medical reports are transferred automatically to corresponding documents. Computer technology has an immense potential for the further development of problem list concepts. With multimedia applications sound and images will be included in the problem list. For hyperlink purpose the problem list could become a central information board and table of contents of the medical record, thus serving as the starting point for database searches and supporting the user in navigating through the medical record.

Electronic Data Processing

Detection of oligonucleotides by external injection into an ion trap storage/reflection time-of-flight device.

The detection of oligonucleotides has been studied using external injection of Matrix-assisted laser desorption/ionization (MALDI) produced ions into a quadrupole ion trap storage device. The ions stored in the trap are then detected by pulsed DC injection into a reflection time-of-flight mass spectrometer. It is shown that by using a low acceleration voltage from the probe tip and external injection into the trap that 3-mers to 9-mers can be stored for 20-50 ms and detected as intact ions. In comparison, direct MALDI inside the trap resulted in extensive fragmentation as a function of storage time. Using the external injection with a He buffer gas in the trap yields a resolution of 250-400 in the ion trap storage/reflectron time-of-flight mass spectrometer. The resolution can be further enhanced to 400-800 using a bipolar extraction method. In addition, the trapping efficiency for the injection of externally produced ions into the trap can be enhanced using a dynamic trapping method. The MALDI mass spectra produced by this methodology result in excellent signal-to-noise ratio due to the capabilities of the trap for eliminating low mass matrix background from the spectra.

Electronic Data Processing