PubMed Health⌕ Search

PubMed · 9177795

A general approach to error estimation and optimized experiment design, applied to multislice imaging of T1 in human brain at 4.1 T.

Abstract

In this report, a procedure to optimize inversion-recovery times, in order to minimize the uncertainty in the measured T1 from 2-point multislice images of the human brain at 4.1 T, is discussed. The 2-point, 40-slice measurement employed inversion-recovery delays chosen based on the minimization of noise-based uncertainties. For comparison of the measured T1 values and uncertainties, 10-point, 3-slice measurements were also acquired. The measured T1 values using the 2-point method were 814, 1361, and 3386 ms for white matter, gray matter, and cerebral spinal fluid, respectively, in agreement with the respective T1 values of 817, 1329, and 3320 ms obtained using the 10-point measurement. The 2-point, 40-slice method was used to determine the T1 in the cortical gray matter, cerebellar gray matter, caudate nucleus, cerebral peduncle, globus pallidus, colliculus, lenticular nucleus, base of the pons, substantia nigra, thalamus, white matter, corpus callosum, and internal capsule.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G F Mason, W J Chu, H P Hetherington. 1997. A general approach to error estimation and optimized experiment design, applied to multislice imaging of T1 in human brain at 4.1 T.. https://doi.org/10.1006/jmre.1997.1143

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗