The serum anion gap. Has the reference interval really fallen?

Abstract

OBJECTIVE: To compare the anion gap (calculated as the sodium concentration minus the sum of the chloride and total carbon dioxide concentrations) reference interval for three automated chemistry analyzers. DESIGN: We measured serum sodium, chloride, and total carbon dioxide on aliquoted specimens using three commercial instruments. Quality control and proficiency survey materials were run to ensure that the analyzers were functioning optimally. SETTING: Three separate clinical laboratories affiliated with one university medical center participated in the study. PARTICIPANTS: Healthy volunteers from 20 to 60 years of age were recruited from within a clinical laboratory. MAIN OUTCOME MEASURES: The mean and standard deviations of the anion gaps measured by each method were calculated. RESULTS: The parametric reference intervals (+/-2 SD from the mean) were 5 to 10 mmol/L for the Beckman Synchron CX3 analyzer, 9 to 14 mmol/L for the Boehringer Mannheim Hitachi 717 analyzer, and 8 to 13 mmol/L for the Johnson & Johnson Vitros 950 analyzer. CONCLUSIONS: Our results suggest that while it may be appropriate to lower the anion gap reference interval to 5 to 10 mmol/L for some analyzers, as suggested by earlier reports, 9 to 14 mmol/L may be a more appropriate reference interval for other analyzers. For the anion gap to be an effective tool for diagnosing acid-base disorders, clinical laboratorians need to establish (or at least verify) the anion gap reference interval for the instrumentation used in their laboratory, inform clinicians of this reference interval, and perform quality control studies to ensure that the reference interval for this calculated result remains valid.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W L Roberts, R D Johnson. 1997. The serum anion gap. Has the reference interval really fallen?. https://pubmed.ncbi.nlm.nih.gov/9199620/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The weighted walking test as an alternative method of assessing aerobic power.

The aim of the present study was to determine maximal oxygen uptake (VO2max) directly during uphill walking exercise and to compare these values with those achieved during running and cycling exercise. Forty untrained students (20 males and 20 females) took part in three exercise tests. The running test was performed on a horizontal treadmill and the speed was gradually increased by 0.3 m . s(-1) every 3 min. The walking test was conducted on a treadmill inclined at 12% (speed of 1.8 m . s(-1)). The load was further increased every 3 min by the addition of a mass of one-twentieth of the body mass of the participant (plastic containers filled with water and added to a backpack carried by the participant). During the bicycle ergometry test, the workload was increased by 20 W every 2 min. All tests were performed until volitional exhaustion. During all tests, oxygen uptake, minute ventilation, tidal volume, respiratory frequency, heart rate, hydrogen ion concentration, base excess, and blood lactate concentration were analysed. The Pearson correlation coefficients between the weighted walking test and the commonly applied running and bicycle ergometry tests indicate a strong association with the new test in evaluating maximal oxygen uptake. The negligible differences in VO2max between the three tests for the male participants (running: 61.0 ml . kg(-1) . min(-1); walking: 60.4 ml . kg(-1) . min(-1); cycling: 60.2 ml . kg(-1) . min(-1)), and the fact that the females achieved better results on the walking test than the cycle ergometer test (running: 45.0 ml . kg(-1) . min(-1); walking: 42.6 ml . kg(-1) . min(-1); cycling: 40.1 ml . kg(-1) . min(-1)), confirm the suitability of the new method for evaluating aerobic power. The weighted walking test could be useful in the assessment of aerobic power in individuals for whom running is not advised or is difficult. In addition, the new test allows for determination of VO2max on small treadmills with a limited speed regulator, such as those found in specialist physiotherapy and fitness centres.

Acid-Base Equilibrium↗

Mandatory protocol for treating adult patients with diabetic ketoacidosis decreases intensive care unit and hospital lengths of stay: results of a nonrandomized trial.

OBJECTIVE: To determine the effect of a mandatory protocol for treating diabetic ketoacidosis. DESIGN: Chart review of patients treated before and after protocol implementation. SETTING: University-affiliated U.S. public teaching hospital. PATIENTS: A total of 241 consecutive nonpregnant patients >18 yrs old admitted to a medical intensive care unit for diabetic ketoacidosis between January 2000 and January 2005. INTERVENTION: Implementation of a mandatory treatment protocol in May 2003. MEASUREMENTS: Intensive care unit and hospital lengths of stay, time to correction of anion gap and ketone clearance, and hypoglycemic episodes. RESULTS: Before protocol implementation, the mean +/- sd intensive care unit and hospital lengths of stay were 44 +/- 28 hrs and 91 +/- 73 hrs, respectively. After implementation, intensive care unit and hospital lengths of stay decreased 23% and 30%, to 34 +/- 18 hrs and 64 +/- 41 hrs, respectively (both p < .007). Time to anion gap closure and ketone clearance also decreased (both p < .05). No difference in the number of hypoglycemic episodes was observed. CONCLUSION: Implementing a mandatory protocol for treating adult patients with diabetic ketoacidosis decreases intensive care and hospital lengths of stay and time to anion gap closure and ketone clearance, without increasing the rate of hypoglycemia.

Acid-Base Equilibrium↗