PubMed Health⌕ Search

PubMed · 9213400

[Endonasal, microscopically controlled frontal sinus surgery].

Abstract

BACKGROUND: The anatomic variation of the frontal sinus and frontal recess can create both a diagnostic and therapeutic challenge. Most cases of frontal sinus disease can now be treated by endoscopic approaches. For refractory cases or those with severe pathology, the microscopically controlled drainage (MCD) operation has at times been successful and spared the patient the morbidity of an external approach. The aim of this study was to evaluate microscopically controlled frontal sinus surgery in these difficult cases. MATERIAL AND METHODS: Prospective analysis was performed on the efficacy of MCD in patients for whom endoscopic sinus surgery had failed or in primary cases with severe pathology or unfavorable anatomy. The technique employs a self-retaining endonasal retractor and a diamond bur under microscopic visualization to remove solid bone (frontal spine) obstructing the sinus drainage and allow a wide opening of the frontal recess while causing minimal mucosal damage. Unilateral drainage (extended frontal sinus drainage operation), and in some cases bilateral drainage (median drainage procedure) is employed. RESULTS: With an average of 23 months of follow-up, over 90% of patients were either free of symptoms or substantially improved after the MCD procedure. Three patients required revision surgery (extend the opening into a median drainage procedure) for adequate relief of symptoms. CONCLUSIONS: The MCD procedure is highly successful in the treatment of frontal recess disease, particularly in those cases of severe pathology or difficult anatomy. It may be used in those cases refractory to standard endoscopic sinus surgery where an external approach and frontal sinus obliteration are contemplated. As with endoscopic sinus surgery, precise knowledge of the frontal recess and neighboring landmarks is critical, and adequate drainage with minimal mucosal disruption should be the goal.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Simmen. 1997. [Endonasal, microscopically controlled frontal sinus surgery].. https://doi.org/10.1055/s-2007-997401

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗