A new method for regularization parameter determination in the inverse problem of electrocardiography.

Abstract

Computing the potentials on the heart's epicardial surface from the body surface potentials constitutes one form of the inverse problem of electrocardiography. An often-used approach to overcoming the ill-posed nature of the inverse problem and stabilizing the solution is via zero-order Tikhonov regularization, where the squared norms of both the surface potential residual and the solution are minimized, with a relative weight determined by a so-called regularization parameter. This paper looks at the composite residual and smoothing operator (CRESO) and L-curve methods currently used to determine a suitable value for this regularization parameter, t, and proposes a third method that works just as well and is much simpler to compute. This new zero-crossing method selects t such that the squared norm of the surface potential residual is equal to t times the squared norm of the solution. Its performance was compared with those of the other two methods, using three stimulation protocols of increasing complexity. The first of these protocols involved a concentric spheres model for the heart and torso and three current dipoles placed inside the inner sphere as the source distribution. The second replaced the spheres with realistic epicardial and torso geometries, while keeping the three-dipole source configuration. The final simulation kept the realistic epicardial and torso geometries, but used epicardial potential distributions corresponding to both normal and ectopic activation of the heart as the source model. Inverse solutions were computed in the presence of both geometry noise, involving assumed erroneous shifts in the heart position, and of Gaussian measurement noise added to the torso surface potentials. It was verified that in an idealistic situation, in which correlated geometry noise dominated the uncorrelated Gaussian measurement noise, only the CRESO approach arrived at a value for t. Both L-curve and zero-crossing approaches did not work. Once measurement noise dominated geometry noise, all three approaches resulted in comparable t values. It was also shown, however, that often under low measurement noise conditions none of the three resulted in an optimum solution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P R Johnston, R M Gulrajani. 1997. A new method for regularization parameter determination in the inverse problem of electrocardiography.. https://doi.org/10.1109/10.553710

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗