Magnetometer spacing criterion for biomagnetic source current imaging.

Abstract

A criterion for determining the maximum spacing between magnetometers for measuring the magnetic field is derived. A two-dimensional (2-D) filter model is employed to determine the maximum spatial frequency component present in the magnetic field that is above the spectral noise level. This maximum frequency component is then sampled at a rate greater than twice per period as indicated by the Nyquist criterion, yielding the required magnetometer spacing. It is shown that the rule-of-thumb employed in current clinical biomagnetic array systems, that the spacing between the coils should be approximately equal to the depth of the source, is adequate when the signal-to-noise power ratio is less than 28.4 (14.5 dB). The analysis also quantitatively demonstrates that reducing the separation between the measurement and source planes has a greater effect on the resolution than decreasing the noise level by the same factor. This result is important for employing high Tc superconductor magnetometers that allow thinner thermal insulating layers at the cost of higher thermal noise.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Kuc. 1996. Magnetometer spacing criterion for biomagnetic source current imaging.. https://doi.org/10.1109/10.541255

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A radiofrequency glow-discharge-time-of-flight mass spectrometer for direct analysis of glasses.

A radiofrequency (rf) glow-discharge (GD) ion source coupled to a commercial on-axis time-of-flight mass spectrometer (TOFMS) has been developed for the direct analysis of non-conducting samples. Different instrumental configurations of the rf-GD source, including the optional use of a sampler cone and the possibility of allowing electrical floating of the discharge, were evaluated first with a conducting sample. Higher ion signals were obtained when the GD was electrically floating and no sampler cone was used. A homogeneous glass was then analyzed using two different rf-GD configurations--with a sampler cone and discarding the use of the sampler cone. The atomic mass spectra obtained with the TOFMS using both configurations were compared. Analyte signals were systematically higher for the latest mode which avoids the sampler cone. The analytical capability of the proposed rf-GD-TOFMS system for the analysis of thick glasses, up to 6 mm, has been investigated in terms of sensitivity, isotopic ratio accuracy, and mass-resolving power. Different homogeneous glasses (including glasses as thick as 6 mm) have been analyzed and major and minor elements were detected. Isotope ratio accuracies of about +/-1% and mass resolving powers of about 700 were observed.

Electromagnetic Fields↗

Dielectrophoretic concentration and separation of live and dead bacteria in an array of insulators.

Insulator-based (electrodeless) dielectrophoresis (iDEP) is an innovative approach in which the nonuniform electric field needed to drive DEP is produced by insulators, avoiding problems associated with the use of electrodes. Live and dead Escherichia coli were concentrated and selectively released by applying stepped DC voltages across a microchannel containing an array of insulating posts etched in glass. The only electrodes present were two platinum wires placed in the inlet and outlet reservoirs, producing mean electric fields of up to 200 V/mm across the insulators. The cells were labeled with Syto 9 and propidium iodide and imaged through a fluorescent microscope. Cell trapping and release were controlled by modifying the relative responses of electrokinesis and DEP by adjusting the magnitude of the applied voltage. Dead cells were observed to have significantly lower dielectrophoretic mobility than live cells, whereas the electrokinetic mobilities of live and dead cells were indistinguishable. The locations of the bands of differentially trapped cells were consistent with predictions. In addition, cells were selectively trapped and concentrated against backgrounds of 1- and 0.2-microm carboxylate-modified polystyrene particles. This first application of iDEP for simultaneous live/dead bacteria separation and concentration illustrates its potential as a front-end method for bacterial analysis.

Electromagnetic Fields↗