PubMed HealthSearch

PubMed · 9219180

Pulsed gradient analysis using a dedicated magnetometer.

Abstract

In magnetic resonance imaging and spectroscopy, knowledge of the magnetic field gradient behavior is very important. This work describes a simple way to characterize the temporal and spatial dependence of the main magnetic field when a gradient is switched. Records are performed with a home-built magnetometer. This device is controlled by a personal computer for recording and processing the NMR signals from an array of small probes spatially distributed and switched by the magnetometer. We present results of measurements on a 2-T superconducting magnet. These results show the residual defects of an active shielded gradient coils system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Desgoutte, L Chaabane, B Favre, A Deguin, C Lapray, A Briguet. 1997. Pulsed gradient analysis using a dedicated magnetometer.. https://doi.org/10.1007/bf02592266

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultra-high-field 7T MRI reveals neural abnormalities of attention networks in relation to cognitive impairment in hypertension.

Hypertension is a significant risk factor for cognitive impairment (CI), yet the corresponding neural network abnormalities remain underexplored. In this study, we examined the associations among global and domain-specific cognitive dysfunction, neuroimaging measures, and blood pressure in a subgroup of hypertensive patients with CI (N = 41) from a randomized controlled trial who underwent ultra-high-field 7 T MRI. Structural atrophy related to CI was localized to regions overlapping the attention networks. Both whole-brain and within-network dysfunction of the attention networks were associated with worse global cognitive performance. Notably, hyperconnectivity within key attention network hubs, including the right anterior insula and posterior intraparietal sulcus, was associated with declined processing speed in hypertensive patients, mediating the association between pulse pressure and processing speed. These findings provide new insights into the neural pathophysiology of hypertension-related CI and suggest potential network-based targets for intervention.

Magnetic Resonance Imaging

Sound generation in gradient coil structures for MRI.

When supporting plates of plastic material are subjected to alternating transverse Lorentz forces while in a strong magnetic field normal to the plate surface, compressional waves within the solid produce a modulation of the plate surface that launches an acoustic wave in air along the magnetic field axis. We have extended our previous theory describing this process to include a detailed description of the formation of an acoustic interference pattern in air described by Fraunhofer diffraction at a distance from the plate surface. The extended theory predicts that the observed acoustic signal midpoint and normal to the plate surface gives a variation with frequency in approximate agreement with our previous measurements. The acoustic output off axis shows acoustic blazing that produces two main diffraction peaks with a splitting inversely proportional to the velocity of sound in the plate material. The new results could have important ramifications for the minimization of sound output in gradient coil design for MRI. A new arrangement of coils is proposed to ameliorate the acoustic output problem centrally and normal to the plate by extending the frequency response of the supporting plates to much higher frequencies. Also presented are estimates of the compressional wave velocities deduced from frequency response data recorded at the center-point of a number of different plates.

Magnetic Resonance Imaging

Estimation of the noise in magnitude MR images.

Magnitude magnetic resonance data are Rician distributed. In this note a new method is proposed to estimate the image noise variance for this type of data distribution. The method is based on a double image acquisition, thereby exploiting the knowledge of the Rice distribution moments.

Magnetic Resonance Imaging