PubMed Health⌕ Search

PubMed · 9246613

Automated protein preparation techniques using a digest robot.

Abstract

Since the introduction of fast analysis methods for peptide mixtures such as MALDI-MS, peptide micropreparation and digest methods have become an important bottleneck in the protein characterization process. We therefore developed and describe here a digest robot capable of processing 30 protein samples in parallel [Houthaeve et al. (1995), FEBS Lett. 376, 91-94]. Briefly, after gel pieces or blots are cut out, they are loaded in flowthrough reactors and these are loaded in a thermocontrolled reactor block. The proteins are then washed, reduced, and alkylated, proteolytically or chemically cleaved, and resulting peptides extracted. The system allows the parallel use of different reagents and enzymes during the same run, and is compatible with RP-HPLC peptide separation and Edman degradation, MALDI-MS, and NanoES-MS/MS. The digest robot is now also commercially available from ABIMED. In an ongoing project aimed at elucidating proteinaceous structures involved in the functional and structural maintenance of the Golgi apparatus, we illustrate the strength of the digest robot for the fast analysis of several proteins. We conclude that the performance of the digest robot is comparable to currently used manual digestion methods. The approach outlined makes sample preparation procedures faster, simpler, and less labor-intensive.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Houthaeve, H Gausepohl, K Ashman, T Nillson, M Mann. 1997. Automated protein preparation techniques using a digest robot.. https://doi.org/10.1023/a%3A1026372302560

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New strategies to screen for endocrine-disrupting chemicals in the Portuguese marine environment utilizing large volume injection-capillary gas chromatography-mass spectrometry combined with retention time locking libraries (LVI-GC-MS-RTL).

A new analytical strategy to screen for endocrine-disrupting chemicals (EDCs) in environmental matrices is presented. The strategy uses solid-phase extraction followed by large volume injection and capillary gas chromatography coupled to mass spectrometry combined with retention time locking libraries (SPE-LVI-GC-MS-RTL). Characterization of the proposed methodology (SPE-LVI-GC-MS) for selected classes of EDCs enabled high reproducibility and robustness at the ultratrace level. The RTL databases used allowed hundreds of non-target semivolatiles (i.e., pesticides, polycyclic aromatic hydrocarbons, polychlorinated biphenyls and other classes of suspected EDCs from a great number of unknown environmental matrices) to be simultaneously screened for in an easy, fast and remarkable manner. The application of the proposed methodology to real environmental samples demonstrated its remarkable selectivity and sensitivity at the ultratrace level. Screening assessments performed on water and sediment matrices from eight Portuguese estuaries and coastal waters identified EDC "hotspots." These EDCs mainly come from agricultural and a wide variety of industrial sources, and include pesticides and pesticide metabolites, phenolic derivatives and polycyclic aromatic hydrocarbons, which are included in the lists of priority substances published by international environmental agencies. The estuaries that contained relatively high levels of pesticides were Guadiana, Sado and Mondego, while Minho, Douro and Formosa showed enhanced levels of phenolic derivatives. Dibutyltin and tributyltin, selected as target compounds to be monitored by SPE-LVI-GC-MS in the selected ion monitoring mode, were shown to be widespread contaminants at trace levels in almost all of the sediment matrices assessed. The reliability of the proposed methodology undoubtedly makes it a valuable tool that could replace other analytical strategies currently used to screen for EDCs present in the environment at ultratrace levels.

Chemistry Techniques, Analytical↗

A faster plant stem-water extraction method.

Oxygen and hydrogen isotope ratios of stem water have been used by several studies which relate the ecophysiology of plants to their water source. Undoubtedly, there are several other applications and research areas which could use this type of analysis. However, the most often used methods of extracting stem water are slow, limiting the rate of sampling and consequently preventing a deeper understanding of spatial and temporal plant water source use. We have developed a faster batch method of stem-water extraction and compare it with the most commonly used online method of stem-water extraction. Samples are sealed in 18 cm long ampoules having their extremities placed sample end in a heating block and the condensing end in a cooling block, and allowed to distill overnight. Up to 72 samples can be distilled overnight and sealed the next morning. The isotope ratios of water distilled by the batch method introduced here compared with those from the online method were in excellent agreement. In addition to being faster, this method does not need the monitoring of hot water baths and liquid nitrogen traps during distillation and does not require a complex vacuum system.

Chemistry Techniques, Analytical↗

Rapid circular microfluidic mixer utilizing unbalanced driving force.

This paper proposes a novel rapid circular microfluidic mixer for micro-total-analysis-systems (mu-TAS) applications in which an unbalanced driving force is used to mix fluids in a circular chamber at low Reynolds numbers (Re). The microfluidic mixer has a three-layered structure and is fabricated on low-cost glass slides using a simple and reliable fabrication process. Using hydrodynamic pumps, fluids are driven from two inlet ports into a circular mixing chamber. Each inlet port separates into two separate channels, which are then attached to opposite sides of the 3-dimensional (3-D) circular mixing chamber. The unequal lengths of these inlet channels generate an unbalanced driving force, which enhances the mixing effect in the mixing chamber. Numerical simulations are performed to predict the fluid phenomena in the mixing chamber and to estimate the mixing performance under various Reynolds number conditions. The numerical results are verified by performing flow visualization experiments. A good agreement is found between the two sets of results. The numerical and experimental results reveal that the mixing performance can reach 91% within a mixing chamber of 1 mm diameter at a Reynolds number of Re=3. Additionally, the results confirm that the unbalanced driving force produces a flow rotation in the circular mixer at low Reynolds numbers, which significantly enhances the mixing performance. The novel micromixing method presented in this study provides a simple solution for mixing problems in Lab-on-a-chip systems.

Chemistry Techniques, Analytical↗