PubMed Health⌕ Search

PubMed · 9286159

Microchip device for performing enzyme assays.

Abstract

An automated enzyme assay was performed within a microfabricated channel network. Precise concentrations of substrate, enzyme, and inhibitor were mixed in nanoliter volumes using electrokinetic flow. Reagent dilution and mixing were controlled by regulating the applied potential at the terminus of each channel, using voltages derived from an equivalent circuit model of the microchip. The enzyme beta-galactosidase (beta-Gal) was assayed using resorufin beta-D-galactopyranoside (RBG), a substrate that is hydrolyzed to resorufin, a fluorescent product. Reaction kinetics were obtained by varying the concentration of substrate on-chip and monitoring the production of resorufin using laser-induced fluorescence. Derived Michaelis--Menten constants compared well between an on-chip and a conventional enzyme assay. Bias in the derived K(m) and kcat was primarily due to the limited solubility of RBG and the associated lack of measurements at substrate concentrations exceeding the K(m). A Ki of 8 microM for the inhibitor phenylethyl beta-D-thiogalactoside (PETG) was determined from plots of initial rate versus substrate concentration obtained at three concentrations of PETG. The relative inhibition of beta-Gal by lactose, p-hydroxymercuribenzoic acid, and PETG was determined by varying the inhibitor concentration with constant enzyme and substrate concentration. An enzyme assay performed on the microchip within a 20-min period required only 120 pg of enzyme and 7.5 ng of substrate, reducing the amount of reagent consumed by 4 orders of magnitude over a conventional assay.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A G Hadd, D E Raymond, J W Halliwell, S C Jacobson, J M Ramsey. 1997-09-01. Microchip device for performing enzyme assays.. https://doi.org/10.1021/ac970192p

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of the Agilent 2100 bioanalyzer for rapid and reproducible molecular typing of Streptococcus pneumoniae.

Restriction fragment length polymorphism (RFLP) analysis is an economic and fast technique for molecular typing but has the drawback of difficulties in accurately sizing DNA fragments and comparing banding patterns on agarose gels. We aimed to improve RFLP for typing of the important human pathogen Streptococcus pneumoniae and to compare the results with the commonly used typing techniques of pulsed-field gel electrophoresis and multilocus sequence typing. We designed primers to amplify a noncoding region adjacent to the pneumolysin gene. The PCR product was digested separately with six restriction endonucleases, and the DNA fragments were analyzed using an Agilent 2100 bioanalyzer for accurate sizing. The combined RFLP results for all enzymes allowed us to assign each of the 47 clinical isolates of S. pneumoniae tested to one of 33 RFLP types. RFLP analyzed using the bioanalyzer allowed discrimination between strains similar to that obtained by the more commonly used techniques of pulsed-field gel electrophoresis, which discriminated between 34 types, and multilocus sequence typing, which discriminated between 35 types, but more quickly and with less expense. RFLP of a noncoding region using the Agilent 2100 bioanalyzer could be a useful addition to the molecular typing techniques in current use for S. pneumoniae, especially as a first screen of a local population.

Autoanalysis↗

A three-armed trial of the ThinPrep Imaging System.

We compared the performance of the ThinPrep (TP) Imaging System (TIS) with manual reading of TP slides (TPM) and with manual reading of the paired conventional Pap smear (PS) in terms of sensitivity for and positive predictive value (PPV) of high-grade disease and productivity. The study consisted of 11,416 routine PS and paired TP slides as well as 103 confirmed abnormal TP slides. In terms of sensitivity for the detection of biopsy-confirmed high-grade disease, overall there was no statistically significant difference between TIS-screened TP (TPI) and TPM (81.1% vs. 86.8%). For the routine cases, TPI was significantly more sensitive than PS (73.4% vs. 57.8%). In terms of PPVs for the cytologic prediction of high-grade disease, there was no statistically, significant difference among TPI, TPM, and PS (75.6%, 73.9%, and 84.6%). For cytologic reports of possible high-grade disease, the PPVs were equivalent for TPI (45.0%) and TPM (37.0%) and there was no significant difference in PPVs between TPI and PS (61.3%). For TP slides, TIS screening showed a 27% productivity gain when compared with manual screening and a 54% productivity gain when compared with manual screening of PS slides. Use of TIS showed productivity benefits when compared with TPM and both productivity and sensitivity benefits over use of PS.