Validation of a revised slow-stop flow recirculation method.

Abstract

Slow flow/stop flow methods have replaced the three needle technique as methods of choice for measuring recirculation. However, the time delay after reducing blood flow may affect the BUN in the systemic (slow flow/stop flow arterial line) sample and therefore limit the accuracy of this methodology. It has been observed that recirculation does not occur in a properly cannulated access unless the access blood flow rate is less than the dialyzer blood flow rate (BFR). This suggests that the systemic sample could be obtained at a higher than usual blood pump rate. We studied 50 patients and compared a revised slow-stop flow (S/SF) recirculation technique in which the systemic sample was drawn after the blood pump rate was reduced to 120 ml/min for 10 seconds and then stopped, to a non-urea based method that utilized indicator velocity dilution (IVDM). Seven patients were found to have recirculation by IVDM; all had recirculation by S/SF of more than 10% (minimum 16.7%) and an access BFR that was less than the dialyzer BFR. In the 43 patients without recirculation by IVDM, the mean recirculation by S/SF was 1.9 +/- 3.2% (mean +/- SD). Five patients without recirculation by IVDM had more than 5% recirculation by S/SF (range, 5.9 to 8.3%). Although there was a small systematic tendency to overestimate recirculation, this modified urea based method was still able to detect recirculation with good reliability. Single values above 10% are highly likely to indicate the presence of true recirculation. Repeated values over 5%, are also likely to be significant, indicating the presence of true recirculation and its clinical correlate, marginal access blood flow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Kapoian, C A Steward, R A Sherman. 1997. Validation of a revised slow-stop flow recirculation method.. https://doi.org/10.1038/ki.1997.402

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A new pressure attenuation index to evaluate retinal circulation. A link to protective factors in diabetic retinopathy.

BACKGROUND: Low ocular perfusion pressure (two thirds of mean arterial pressure minus intraocular pressure) and myopia have been associated with protection of the retina from clinical diabetic retinopathy. This prompts the question as to whether myopia's protective role could also be a pressure effect, given that pressure could be dissipated in the longer arteriole tree of the myopic eye. METHODS: We combined the Ohm, Poiseuille, and Murray laws to derive the following new formulation: the pressure attenuation along a vessel varies directly with its length and inversely with its diameter. A mean pressure attenuation index was calculated for 22 healthy control subjects, 25 patients with axial myopia, and 6 patients with retinitis pigmentosa using digitized fundus images. RESULTS: The myopic arteriolar tree would produce a 16% greater pressure attenuation than that of controls (P = .002), with a linear relationship between mean pressure attenuation index and axial length (r = 0.93). Mean pressure attenuation index of the group with retinitis pigmentosa is increased 67% above that of controls, which is calculated to contribute an additional 10 mm Hg of pressure dissipation along their retinal arteriolar system. CONCLUSIONS: Pressure attenuation in retinal arterioles is directly proportional to the length and inversely proportional to the diameter of the arteriole segment being measured. CLINICAL RELEVANCE: A pressure attenuation index may be important in light of the entities known or presumed to protect the retina from diabetic retinopathy. The results support the hypothesis that low-end arteriolar pressure is a common denominator for many protective conditions in diabetic retinopathy.

Blood Circulation

Should clinical cardiologists report total peripheral resistance or total peripheral conductance?

Regional and total vascular tone have traditionally been assessed by using calculated resistance as the index. However, in most situations, regional flow or cardiac output changes over a much wider range than does blood pressure. With flow in the denominator (resistance), the index is nonlinearly related to the changing parameter, thus rendering even simple arithmetic means inaccurate. Vascular conductance uses flow in the numerator and results in an index that is linearly related to flow, thus enabling a variety of relationships to be demonstrated that are concealed or distorted when studied by the use of vascular resistance.

Blood Circulation

Umbilical arterial S-nitrosothiols in stressed newborns: role in perinatal circulatory transition.

S-Nitrosothiols are potent endogenous vasodilators recently found to be in greater concentrations in fetal umbilical venous than arterial blood. We hypothesized that neonatal increases in SNOs may be involved in the normal human perinatal circulatory transition. Paired human umbilical artery and vein plasma samples were collected after birth. S-Nitrosothiol concentrations were measured as NO after photolysis--and NO3- after reduction in vanadium chloride--by chemiluminescence. Normal umbilical arterial serum SNO levels were nearly twice those of matched venous samples but were low in infants who did not transition normally to neonatal circulation. There was no difference in the concentration of NO3- between the normal and depressed infants. The parallel failure of some fetuses to switch both to a normal arteriovenous SNO relationship and a normal clinical post-partum state suggests that SNOs may be involved in the perinatal circulatory transition.

Blood Circulation