PubMed Health⌕ Search

PubMed · 9302466

Hyperbaric oxygen therapy for acute ankle sprains.

Abstract

We conducted a randomized double-blind study of 32 subject with acute ankle sprains to compare treatment with hyperbaric oxygen at 2 atmospheres absolute pressure (N = 16) (treatment group) with treatment with air at 1.1 atmosphere absolute pressure (N = 16) (control group) in a hyperbaric chamber. Each group received three treatments at their respective pressures: one for 90 minutes and two for 60 minutes each. Mean age, severity grade, and time to treatment (treatment group, 34.3 +/- 6.3 hours; control group, 32.6 +/- 4.6 hours) were similar in both groups. Joint function measured by a functional index improved from 0.40 +/- 0.2 to 6.3 +/- 0.4 with hyperbaric oxygen and from 0.8 +/- 0.3 to 5.3 +/- 0.6 with air. The change from initial to final evaluation was significantly greater in the treatment group. Foot and ankle volume by water displacement decreased from 1451 +/- 57 ml to 1425 +/- 63 ml with hyperbaric oxygen and from 1403 +/- 50 ml of 1371 +/- 45 ml with air (no difference was noted between hyperbaric oxygen treatment and air treatment using a two-day analysis of variance). Subjective pain index fell from 3.3 +/- 0.5 to 0.8 +/- 0.3 with hyperbaric oxygen and from 2.6 +/- 0.3 to 0.3 +/- 0.2 with air. No differences were noted in passive or active range of motion when comparing hyperbaric oxygen treatment with air treatment. Time to recovery was the same in both groups (treatment, 16.0 +/- 6.3 days; control, 15.4 +/- 2.8 days). Regression analysis to determine the influence of time to treatment, initial severity of injury, hyperbaric oxygen, and age showed no effect of hyperbaric oxygen treatment on time to recovery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C N Borromeo, J L Ryan, P A Marchetto, R Peterson, A A Bove. Hyperbaric oxygen therapy for acute ankle sprains.. https://doi.org/10.1177/036354659702500506

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗