Managing bone loss with augmentation.

Abstract

Augmentation blocks are effective ways of treating the problem of bone loss on the distal and posterior femur. They allow accurate and durable reestablishment of the distal and posterior joint line in revision total knee replacements. They are particularly appropriate in revisions being carried out in elderly, osteopenic patients with severe deformities or instabilities. Revision instrumentation can and should philosophically and mechanically remind one of and be consistent with primary total knee instrumentation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S D Stulberg. 1997. Managing bone loss with augmentation.. https://doi.org/10.3928/0147-7447-19970901-28

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Biodegradable polymer/hydroxyapatite composites: surface analysis and initial attachment of human osteoblasts.

Biodegradable polymer/hydroxyapatite (HA) composites have potential application as bone graft substitutes. Thin films of polymer/HA composites were produced, and the initial attachment of primary human osteoblasts (HOBs) was assessed to investigate the biocompatibility of the materials. Poly(epsilon-caprolactone) (PCL) and poly(L-lactic acid) (PLA) were used as matrix materials for two types of HA particles, 50-microm sintered and submicron nonsintered. Using ESEM, cell morphology on the surfaces of samples was investigated after 90 min, 4 h, and 24 h of cell culture. Cell activity and viability were assessed after 24 h of cell culture using Alamar blue and DNA assays. Surface morphology of the polymer/HA composites and HA exposure were investigated using ESEM and EDXA, respectively. ESEM enabled investigation of both cell and material surface morphology in the hydrated condition. Combined with EDXA it permitted chemical and visual examination of the composite. Differences in HA exposure were observed on the different composite surfaces that affected the morphology of attached cells. In the first 4 h of cell culture, the cells were spread to a higher degree on exposed HA regions of the composites and on PLA than they were on PCL. After 24 h the cells were spread equally on all the samples. The cell activity after 24 h was significantly higher on the polymer/HA composites than on the polymer films. There was no significant difference in the activity of the cells on the various composite materials. However, cells on PCL showed higher activity compared to those on PLA. A polymer surface exhibiting "point exposure" of HA appeared to provide a novel and favorable substrate for primary cell attachment. The cell morphology and activity results indicate a favorable cell/material interaction and suggest that PLA and PCL and their composites with HA may be candidate materials for the reconstruction of bony tissue. Further investigations regarding long-term biomaterial/cell interactions and the effects of acidic degradation products from the biodegradable polymers are required to confirm their utility.

Bone Substitutes↗

Immunoglobulin enhances the bioactive-glass-induced chemiluminescence response of human polymorphonuclear leukocytes.

Bioactive glasses are bone substitutes that chemically bind to bone. Implanted materials always elicit a response from surrounding tissues and thereby can activate inflammatory cells, with subsequent release of biomaterial and tissue-damaging agents. Bioactive glasses can activate polymorphonuclear leukocytes (PMNL) and induce a release of reactive oxygen metabolites (ROM). Adsorption of proteins on the surface of the implanted material may influence the subsequent inflammatory cell response. The effect of Sandoglobulin(R) (SG) and albumin on the ROM release by PMNLs induced by a bioactive glass was studied by a chemiluminescence (CL) assay. An enhanced effect for SG and inhibitory effect for albumin on the CL response of PMNLs was observable. The CL response of the PMNLs was dependent on the incubation time of the glass in solution.

Bone Substitutes↗

Effect of hydroxyapatite sintering temperature on intracellular ionic concentrations of monocytes: a TEM-cryo-X-ray microanalysis study.

Hydroxyapatite used as bone replacement can lead to particle release in the implantation site. These particles interact with monocytes, which are the first immune cells to colonize the implant and an inflammatory site. Thanks to cryo-X-ray microanalysis, we can observe cells in a state close to the physiological one and we have access to diffusible ions. We paid particular attention to the potassium-to-sodium ratio, which is one of the best viability criteria. We used this method to study the interaction between three hydroxyapatite particles treated at three different temperatures (not treated, treated at 600 degrees C and 1180 degrees C), and monocytes. In the culture condition, the hydroxyapatite treated at 1180 degrees C underwent the least dissolution. We demonstrate that monocytes were altered by the three hydroxyapatite particles. The hydroxyapatite particules treated at 600 degrees C were found to be more toxic.

Bone Substitutes↗