X-ray tubes.

Abstract

The x-ray tube serves the function of creating x-ray photons from electric energy supplied by the x-ray generator. The process of creating the x-ray beam is very inefficient, with only 1% of the electric energy converted to x-ray photons and the remaining 99% converted to heat in the x-ray tube assembly. Thus, to produce sufficient x-ray output for diagnostic imaging, the x-ray tube must withstand and dissipate a substantial heat load, a requirement that affects the design and composition of the x-ray tube. The major x-ray tube components are the cathode and anode assemblies, the tube envelope, the rotor and stator (for rotating anode systems), and the tube housing. The design of the x-ray tube determines the basic characteristics of the x-ray beam such as focal spot size, x-ray field uniformity, and the x-ray energy spectrum. These x-ray beam characteristics are important because they affect radiologic parameters such as spatial resolution, image contrast, and patient dose.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F E Zink. X-ray tubes.. https://doi.org/10.1148/radiographics.17.5.9308113

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Longitudinal image deblurring in spiral CT.

PURPOSE: To assess the feasibility of digital deconvolution techniques to improve longitudinal resolution of spiral computed tomography (CT) multiplanar reformations and evaluate how technical factors in deconvolution affect longitudinal resolution, noise, and edge ringing. MATERIALS AND METHODS: Longitudinal line spread function (LSF) of the system was estimated from longitudinal reformations of transaxial spiral CT images of a step test phantom. By using the estimated LSF, longitudinal reformations of the phantom and three clinical spiral CT studies were deconvolved by the methods of Wiener filtering and constrained iterative deconvolution. Edge ringing and image noise were quantified for Wiener filtering and constrained iterative deconvolution. RESULTS: Longitudinal reformations were substantially deblurred and resolution improved after deconvolution. Anatomic boundaries in clinical images were more clearly delineated after restoration. The methods of Wiener deconvolution and constrained iterative deconvolution improved the sharpness of the phantom step boundary at the expense of increased edge ringing and image noise. CONCLUSION: In longitudinal spiral CT reformations, blurring along the longitudinal axis can be reduced by Wiener filtering or constrained iterative deconvolution.

Technology, Radiologic

Re: Film processing.

Explore the source record for details and available documents.

Technology, Radiologic