PubMed Health⌕ Search

PubMed · 9308738

Coagulation disorders caused by hydroxyethyl starch.

Abstract

Initially, hydroxyethyl starch (HES) was only characterized by its in vitro molecular weight (MW). This is not sufficient because HES is degraded in vivo. One relevant parameter that predicts the rate of enzymatic breakdown is the degree of substitution, a measure of the average number of hydroxyethyl groups per glucose unit. The higher this degree of substitution, the slower the break-down. In addition, because the glucose units can be substituted at carbon 2, 3 and 6, different substitution patterns are possible. They are classified by their C2/C6 hydroxyethylation ratio. A higher C2/C6 ratio results in less metabolism of the starch in vivo and results in a larger in vivo MW. This in turn affects therapy, because the larger the in vivo MW, the longer is the duration of the volume effect of HES. Of particular importance is the fact that HES with a high in vivo MW affects factor VIII/von Willebrand factor which can lead to an acquired von Willebrand syndrome. During a 10-day volume therapy with a medium-MW HES 200, a form that is difficult to metabolize, we observed an 80% drop in factor VIII/von Willebrand factor. Therapy with a medium-MW HES 200, a form that is easily degraded, and therapy with a low-MW HES 70 did not result in a relevant decline of factor VIII/von Willebrand factor. This explains why hemorrhagic complications have been observed repeatedly in the United States after therapy with HES infusions, some of them lethal. In the United States high-MW HES 480 which is difficult to degrade is most frequently used and results in a larger in vivo MW and subsequent decrease in factor VIII/von Willebrand factor levels. In Europe, medium-MW HES 200 that is easily degraded and low-MW HES 70 are preferred. In the future, HES should be characterized by the in vivo, not the in vitro MW.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Treib, A Haass, G Pindur. 1997. Coagulation disorders caused by hydroxyethyl starch.. https://pubmed.ncbi.nlm.nih.gov/9308738/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Molecular characterization of an Italian patient with plasminogen deficiency and ligneous conjunctivitis.

Plasminogen deficiency is a rare disease characterized by ligneous conjunctivitis and infections. We observed a 3-year-old Italian boy presenting ligneous conjunctivitis and low plasma levels of plasminogen. Twenty-three different mutations on the PLG gene have been reported to date, but mutation analysis had been troublesome for the presence of highly homologous genes. The aim of the study was to identify the underlying mutation avoiding coamplification of unwanted genetic materials using a long polymerase chain reaction strategy, instead of the previously reported subcloning methods. By this simple strategy the complete sequence analysis of PLG gene was performed, and a previously reported missense homozygous mutation (K19E) was identified.

Blood Coagulation Disorders↗

Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography.

BACKGROUND: Reagent-supported thromboelastometry with the rotation thrombelastography (e.g. ROTEM) is a whole blood assay that evaluates the visco-elastic properties during blood clot formation and clot lysis. A hemostatic monitor capable of rapid and accurate detection of clinical coagulopathy within the resuscitation room could improve management of bleeding after trauma. OBJECTIVES: The goals of this study were to establish whether ROTEM correlated with standard coagulation parameters to rapidly detect bleeding disorders and whether it can help to guide transfusion. METHODS: Ninety trauma patients were included in the study. At admission, standard coagulation assays were performed and ROTEM parameters such as clot formation time (CFT) and clot amplitude (CA) were obtained at 15 min (CA(15)) with two activated tests (INTEM, EXTEM) and at 10 min (CA(10)) with a test analyzing specifically the fibrin component of coagulation (FIBTEM). RESULTS: Trauma induced significant modifications of coagulation as assessed by standard assays and ROTEM. A significant correlation was found between prothrombin time (PT) and CA(15)-EXTEM (r = 0.66, P < 0.0001), between activated partial thromboplastin time and CFT-INTEM (r = 0.91, P < 0.0001), between fibrinogen level and CA(10)-FIBTEM (r = 0.85, P < 0.0001), and between platelet count and CA(15)-INTEM (r = 0.57, P < 0.0001). A cutoff value of CA(15)-EXTEM at 32 mm and CA(10)-FIBTEM at 5 mm presented a good sensitivity (87% and 91%) and specificity (100% and 85%) to detect a PT > 1.5 of control value and a fibrinogen less than 1 g L(-1), respectively. CONCLUSIONS: ROTEM is a point-of-care device that rapidly detects systemic changes of in vivo coagulation in trauma patients, and it might be a helpful device in guiding transfusion.

Blood Coagulation Disorders↗