PubMed Health⌕ Search

PubMed · 931671

External buckling without drainage.

Abstract

Scleral buckling without drainage of subretinal fluid is a technique suitable to a broad range of detachment problems including aphakia, vitreous traction, multiple tears, high myopia, and large breaks, as well as old or extensive detachment. Retinal detachments operated on by modification to the Custodis procedure reattach in a spontaneous and predictable manner determined by the patient's age, the duration of the detachment, and its extent. Ninety percent of cases are completely reattached four days following surgery. Clues to successful surgery when subretinal fluid persists are retinal tear closure, documented daily fluid loss, macular reattachment, and dependent shifting of subretinal fluid. When uncertainty still exists, the final objective evaluation is the observation that fluid fails to accumulate beneath the retina when the patient is unpatched and mobilized. The operation is extraocular and avoids the problems of drainage-choroidal hemorrhage, retinal incarceration, vitreous loss, and restoration of hypotony. The technique offers the modern surgeon a simple, direct, and rational approach applicable to 75 percent of retinal detachments, and it also assures a smooth, uncomplicated recovery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P R O'Connor. 1976. External buckling without drainage.. https://doi.org/10.1097/00004397-197601610-00011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗