PubMed · 932951
Errors involved in instantaneous intravascular input assumptions.
Abstract
A comparative evaluation of a zero-order input and the generally accepted instantaneous intravascular input assumption is made for two- and three-compartment open model systems. Equations are derived and a nomogram is prepared to calculate the magnitude of error involved in instantaneous input assumptions. It is suggested that all intravascular administrations be considered as zero-order inputs.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
S Niazi. 1976. Errors involved in instantaneous intravascular input assumptions.. https://doi.org/10.1002/jps.2600650534
Cite the original work for its findings. Save a collection to share your selection of sources.