Errors involved in instantaneous intravascular input assumptions.

Abstract

A comparative evaluation of a zero-order input and the generally accepted instantaneous intravascular input assumption is made for two- and three-compartment open model systems. Equations are derived and a nomogram is prepared to calculate the magnitude of error involved in instantaneous input assumptions. It is suggested that all intravascular administrations be considered as zero-order inputs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Niazi. 1976. Errors involved in instantaneous intravascular input assumptions.. https://doi.org/10.1002/jps.2600650534