OBJECTIVE: To determine the effect on in vitro dissolution from cutting methylphenidate extended-release tablets in half. DESIGN: Ritalin-SR (Ciba Pharmaceutical Co.) and generic methylphenidate extended-release (MD Pharmaceutical Inc.) tablets were dissolved in water according to the method prescribed by the US Pharmacopeia under two conditions: whole and halved. Samples were collected at 15, 30, and 45 minutes and at 1, 2, 3, 3.5, 4, 5, 6, and 7 hours. Methylphenidate content was determined by HPLC. RESULTS: Halving the tablets caused a statistically significant increase in cumulative dissolution as early as 15 minutes. The difference in cumulative dissolution reached its maximum for both Ritalin-SR and generic methylphenidate extended-release tablets at 2 hours. At this time point, the percent dissolution of the whole versus halved tablets was 57% versus 74% (Ritalin-SR), respectively, and 49% versus 67% (generic), respectively. The dissolution profiles of halved and whole extended-release methylphenidate tablets were parallel from this point through the 7-hour collection period. At 7 hours, however, there was no difference in the cumulative dissolution of halved versus whole tablets. CONCLUSIONS: While statistical differences during in vitro dissolution do exist and pharmacokinetic ramifications have not yet been determined, the absolute differences in dissolution between halved and whole tablets are not great. Halving methylphenidate extended-release tablets may be a clinically acceptable means of achieving a small increment/decrement in dose without converting to a regular-release tablet.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Erramouspe, E J Jarvi. 1997. Effect on dissolution from halving methylphenidate extended-release tablets.. https://doi.org/10.1177/106002809703101001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development of a liquid chromatography-mass spectrometric method for measuring the binding of memantine to different melanins.

A sensitive and selective liquid chromatography-mass spectrometric method was validated for the determination of free memantine in melanin binding studies. The sources of melanin studied were sepia, synthetic and bovine melanin. Memantine was chromatographed on a reversed-phase column (Prodigy 5 microm, ODS(3), 100 A, 100 x 4.6 mm) using gradient elution with mobile phases of 0.1% formic acid in deionised water and 0.1% formic acid in methanol at a flow-rate of 0.8 ml/min. The mode of ionisation was atmospheric pressure-electrospray and detection by single ion monitoring of the memantine ion m/z 180. Validation of the method showed that the assay was linear from 0.1 to 1200 nM and 0.5 to 1200 nM memantine in deionised water and phosphate-buffered saline (PBS), respectively. Accuracy for sample preparations in deionised water was between 80 and 108% and between 80 and 123% for PBS. For both media, intra- and inter-day precision was below 1% for retention time and below 5% for analyte peak area. At the LLOQ, the variation of peak area was less than 17%. Binding of memantine to melanin was measured indirectly by determining the unbound fraction of memantine. After incubation of melanin with memantine, the sample was centrifuged and filtered to separate the memantine-melanin complex effectively from suspension. The filtrate was then assayed for free memantine from which the extent of binding was then calculated.

Chromatography, High Pressure Liquid↗

Development and validation of a liquid chromatography-tandem mass spectrometric assay for Eplerenone and its hydrolyzed metabolite in human plasma.

A sensitive and specific liquid chromatography-tandem mass spectrometry assay was developed to quantify the first selective aldosterone blocker Eplerenone (I) and its hydrolyzed metabolite (II) in human plasma. The analytes (I, II) and their stable isotope-labeled analogues as internal standards were extracted on a C(18) solid-phase extraction cartridge using a Zymark RapidTrace automation system. The chromatographic separation was carried out on a narrow-bore reversed-phase Zorbax XDB-C(8) HPLC column with a mobile phase of acetonitrile/water (40:60, v/v) containing 10 mM ammonium acetate (pH 7.4). The analytes were ionized using negative-to-positive switch electrospray mass spectrometry, then detected by multiple reaction monitoring with a tandem mass spectrometer. The precursor to product ion transitions of m/z 415-->163 and m/z 431-->337 was used to measure I and II, respectively. The assay exhibited a linear dynamic range of 10-2500 ng/ml of plasma for both I and II. The lower limit of quantification was 10 ng/ml for I and II. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A throughput of 80 human plasma standards and samples per run was achieved with run time of 5 min for each injection. The assay has been successfully used in analyses of human plasma samples to support clinical studies.

Chromatography, High Pressure Liquid↗

Determination of fifteen nucleotides in cultured human mononuclear blood and umbilical vein endothelial cells by solvent generated ion-pair chromatography.

The paper describes the development of a method for the determination of 15 nucleotides in cultured mononuclear blood and umbilical vein endothelial cell lysates by solvent generated ion-pair chromatography. The phase system is generated via a mobile phase of 100 mM phosphoric acid adjusted to pH 6.2 with triethylamine. Nucleotides are eluted by applying a linear magnesium ion gradient. The method is robust, highly reproducible and easily adaptable to other cell lysates and allows the separation and quantitation of the nucleotides with detection limits in the range from 17 (ADP) to 126 (CDP) pmol in 20-microl aliquots.

Chromatography, High Pressure Liquid↗