PubMed Health⌕ Search

PubMed · 9340329

[Cochlear implants].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Marangos. 1997. [Cochlear implants].. https://pubmed.ncbi.nlm.nih.gov/9340329/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of reduced dynamic range on speech understanding: implications for patients with cochlear implants.

OBJECTIVE: To determine the effect of reduced dynamic range on speech understanding when the speech signals are processed in a manner similar to a 6-channel cochlear implant speech processor. DESIGN: Signals were processed in a manner similar to a 6-channel cochlear implant processor and output as a sum of sine waves with frequencies equal to the center frequencies of the analysis filters. The amplitudes of the sine waves were compressed in a systematic fashion to simulate the effect of reduced dynamic range. The compressed signals were presented to 10 normal-hearing listeners for identification. RESULTS: There was a significant effect of compression for all test materials. The effect of the compression on speech understanding was different for the three test materials (vowels, consonants, and sentences). Vowel recognition was affected the most by the compression, and consonant recognition was affected the least by the compression. Feature analysis indicated that the reception of place information was affected the most. Sentence recognition was moderately affected by the compression. CONCLUSIONS: Dynamic range should affect the speech perception abilities of cochlear implant users. Our results suggest that a relatively wide dynamic range is needed for a high level of vowel recognition and a relatively small dynamic range is sufficient to maintain consonant recognition. We infer from this outcome that, if other factors were held equal, an implant patient with a small dynamic range could achieve moderately high scores on tests of consonant recognition but poor performance on vowel recognition, and that it is more likely for an implant patient with a large dynamic range to obtain high scores on vowel recognition than for an implant patient with a small dynamic range.

Cochlear Implants↗

Localization of cochlear implant electrodes in radiographs.

Multielectrode cochlear implantation is the most effective treatment for profound sensorineural hearing loss. In vivo three-dimensional 3-D localization of cochlear implant electrodes is important for modeling of the electrical field in the cochlea, design of electrode arrays, and may improve speech processor programming for better speech recognition. The prerequisite for 3-D localization of the electrodes is their 2-D localization in x-ray radiographs. In this paper, we develop a practical method to localize the electrodes with high efficiency, accuracy, and reproducibility. In this method, a priori knowledge of the electrodes and their approximate positions are utilized, an intelligent thresholding and segmentation mechanism is embedded, and the electrode center is computed as the weighted geometric center of segmented electrode pixels. Experiments with physical phantoms and human data demonstrate the feasibility and utility of this method. The PC-based program developed for this project is disseminated on the Web.

Cochlear Implants↗