PubMed Health⌕ Search

PubMed · 9347371

Changes in left ventricular function in shocked newborns.

Abstract

OBJECTIVE: To assess whether the change in cardiac output after volume replacement is due to elevation of stroke volume or heart rate and to determine the effect of mechanical ventilation on the hemodynamic situation. DESIGN: Prospective study. SETTING: A ten-bed neonatal intensive care unit (level III) at a university hospital. PATIENTS: 15 consecutive newborns with blood pressure below the 10th percentile related to age and weight. INTERVENTIONS: Volume replacement with Ringer's lactate 20 ml/kg body weight. MEASUREMENTS AND RESULTS: Before and after volume replacement, arterial pressure recordings, blood gas analysis, and an echocardiographic study were carried out. Left ventricular and aortic diameters were measured by the two-dimensional M-mode technique and velocity time integral of aortic flow by the pulsed color Doppler technique. From these data, stroke volume and cardiac output were calculated. Cardiac output (703 +/- 204 vs 826 +/- 166 ml/ min, p < 0.005) and cardiac index (267 +/- 69 vs 302 +/- 55 ml/min per kg body weight, p < 0.01) changed significantly due to an appreciable elevation in stroke volume (5.2 +/- 1.7 vs 5.8 +/- 1.7 ml, p < 0.05), whereas heart rate was unaltered (140 +/- 12 vs 142 +/- 20 beats/min; NS). The change in blood pressure (32 +/- 5 vs 38 +/- 8 mm Hg, p < 0.01) was also significant. Cardiac index before and after volume replacement showed a significant inverse correlation with the severity of respiratory disease expressed as alveolar-arterial oxygen difference (A-aDO2) (A-aDO2 vs cardiac index before volume replacement: r = -0.77, p < 0.001; after volume replacement: r = -0.73, p < 0.005) or oxygenation index (oxygenation index vs cardiac index before volume replacement: r = -0.73, p < 0.005; after volume replacement: r = -0.73, p < 0.005). Changes in left ventricular diastolic diameter, left ventricular systolic diameter, and fractional shortening were not significant. CONCLUSIONS: These results indicate that the major regulator of left ventricular output in newborns with hypovolemic or cardiogenic shock is stroke volume and not heart rate and that cardiac output depends on the severity of the respiratory disease.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Simma, M G Fritz, R Trawöger, R Geiger, C Fink, I Hammerer. 1997. Changes in left ventricular function in shocked newborns.. https://doi.org/10.1007/s001340050442

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Effect of P(ET)CO(2) monitoring on cardiac function during hepatectomy].

OBJECTIVE: To investigate the relationship between end-tidal Pco2 (P(ET)CO(2)) and cardiac output (CO) during hepatectomy. METHOD: Swan-Ganz catheter was inserted into the right jugular vein of twenty-one patients undergoing hepatectomy to observe the hemodynamic parameters. Cardiac output (CO) was examined by thermodilution technique. Mechanical ventilation was performed after anaesthesia induction, and P(ET) CO(2) was monitored continuously. The relationship between CO and P(ET)CO(2) was analyzed. RESULTS: A strong positive correlation was found between P(ET)CO(2) and CO, r =0.90, P < 0.05. CONCLUSION: P(ET)CO(2) can be used as a predictor of CO. This technique is safe, simple and can be used in hemodynamic unstable patients during the major surgical procedure and in patient with poor cardiac function.

Cardiac Output↗

Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution.

OBJECTIVE: To determine the relationship between the degree of tricuspid regurgitation (TR) and accuracy of cardiac output measurement by thermodilution in mechanically ventilated patients. DESIGN AND SETTING. Prospective observational study in a 20-bed general intensive care unit in the university hospital. PATIENTS: We examined 27 patients (not undergoing cardiac surgery): 8 with no or 1st degree TR, 9 with 2nd degree, and 10 with 3rd degree TR. INTERVENTIONS: All patients were measured twice using simultaneously transesophageal echocardiography and pulmonary artery catheter for cardiac output. MEASUREMENTS AND RESULTS: Continuous Doppler measurements were taken in the left ventricular outflow tract at the level of the aortic valve. Cardiac output was calculated by multiplying the velocity-time integral by aortic valve area and heart rate. Simultaneous pulmonary artery catheter measurements were taken averaging the results of the three 10-cc boluses of iced saline. The difference between the methods was 0.5+/-1.1 l/min (mean +/-2 SD) in patients with no or 1st degree TR (r=0.96), 0.8+/-2.0 l/min in those with 2nd degree TR (r=0.92), and 1.9+/-2.3 l/min in those with 3rd degree TR (r=0.69). CONCLUSIONS: A high degree of TR is associated with underestimation of cardiac output measured by thermodilution.

Cardiac Output↗