PubMed · 9359543

Lead system optimization for transvenous defibrillation.

Abstract

Lead systems that include an active pectoral shell reduce defibrillation thresholds and permit transvenous defibrillation in nearly all patients. A further improvement in defibrillation efficacy is desirable to allow for smaller pulse generators with a reduced maximum output. Accordingly, the purpose of this study was to compare defibrillation thresholds with multiple transvenous lead systems including those with an active pectoral shell to determine which system would optimize defibrillation energy requirements. This prospective study was performed on 21 consecutive patients. Each subject was evaluated with 3 lead configurations with the order of testing randomized. The configurations were a dual coil transvenous lead (lead), the distal right ventricular coil and pectoral pulse generator shell (unipolar), and all 3 components (triad). The right ventricular coil was the cathode for the first phase of the biphasic defibrillation waveform. Delivered energy at defibrillation threshold was 11.2 +/- 3.4 J for the lead configuration, 10.1 +/- 5.2 J for the unipolar configuration, and 7.8 +/- 3.6 J for the triad configuration (p <0.01). Leading edge voltage (p <0.01) and shock impedance (p <0.001) were also decreased for the triad configuration compared with the lead or unipolar configurations, whereas peak current was minimized with the unipolar configuration (p <0.01). We conclude that the combination of a dual coil, transvenous lead and an active pectoral shell reduces defibrillation energy requirements compared with either the lead alone or unipolar configuration. Moreover, the defibrillation thresholds were < or =15 J in all patients using the triad lead system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M R Gold, A H Foster, S R Shorofsky. 1997-11-01. Lead system optimization for transvenous defibrillation.. https://doi.org/10.1016/s0002-9149(97)00633-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

ICD therapy in the new millennium.

Remarkable progress has been made in the 15 years since ICD therapy was approved for human use. The early "shock boxes" had almost no diagnostic capabilities and required thoracotomy for epicardial patch implantation with typical duration of hospitalization of about a week. Pulse-generator longevity was less than 2 years. Modern devices provide detailed information about the morphology and rate of electrocardiographic signals before, during, and after arrhythmia therapy. The down-sizing of pulse generators and improvements in lead design and shock waveforms allow the simplicity of defibrillator implantation to approach that of pacemakers, with defibrillation thresholds comparable with those initially observed with epicardial patches. Despite the marked reduction in size and increase in diagnostic capabilities, device longevity is now longer than 6 years. Routine outpatient ICD implantation is presently feasible and will increase in frequency if ongoing primary prevention trials prove beneficial. Further advances in lead technology and arrhythmia discrimination should increase the efficacy and reliability of therapy. Finally, devices have the capabilities to treat multiple problems in addition to life-threatening ventricular arrhythmias including atrial arrhythmias and congestive heart failure.

Defibrillators, Implantable↗

Laser surgery in a patient with Romano-Ward (long QT) syndrome and an automatic implantable cardioverter defibrillator.

A 48-year-old woman with Romano-Ward syndrome (a hereditary long QT syndrome), asthma and an automatic implantable cardioverter defibrillator presented for laser surgery for debulking of a massive nasopharyngeal tumour prior to radiotherapy. Automatic implantable cardioverter defibrillators have only relatively recently been used to treat patients with the long QT syndrome and are indicated for the high-risk individual when conventional treatment has failed or when beta-blockers are contraindicated. If surgery requires the use of surgical diathermy, a cardiac technician must be present to deactivate the defibrillator and external pacing electrodes are sited on the chest until the defibrillator can be reactivated. Radiotherapy requires both deactivation and shielding of the device.

Defibrillators, Implantable↗