PubMed Health⌕ Search

PubMed · 9360125

Development of a custom designed TAH using rapid prototyping.

Abstract

The failure of the orthotopic implantation of a totally implantable artificial heart (TAH) was due mainly to anatomic mismatches in the conduits of the conventional TAH system. To overcome this anatomic incompatibility, a custom design and fabrication process was designed using the rapid prototyping (RP) technique. After three dimensional reconstruction of magnetic resonance imaging of the thoracic cavity and vascular remnants of the recipient, study of anatomic fit was done using the reconstructed thoracic model and three dimensional computer aided design (CAD) model. The direction of the inflow and outflow conduits of the blood sac was changed with a Unigraphics CAD. The RP model of the designed chamber was fabricated and examined for anatomic compatibility. Through this approach, the minute directional mismatch of the inflow and outflow conduits was improved. Thus, a new custom designed moving actuator Korean TAH with CAD and RP techniques was developed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Y Park, J K Chang, D Y Jeong, G J Yoon, C Chung, J K Kim, D C Han, B G Min. Development of a custom designed TAH using rapid prototyping.. https://pubmed.ncbi.nlm.nih.gov/9360125/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗