PubMed Health⌕ Search

PubMed · 9363624

Postmortem skeletal lesions.

Abstract

Postmortem bone alterations are very frequent and can raise the issue of their nature (antemortem, perimortem or postmortem defects). The aim of this work is to study various aspects of defects which were not assessed as perimortem trauma, from a series of 50 defects examined, resulting from 24 forensic cases. This study emphasizes the variability of size, shape and number of postmortem defects. Usually the diagnosis of antemortem defects is helped by a careful examination of some characteristics as the edges of the defects, the areas of discoloration of the edges and of the whole bone. Elsewhere it appears very difficult to know the true nature (antemortem, postmortem, or perimortem alterations) of the bone.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Quatrehomme, M Y Işcan. 1997-10-06. Postmortem skeletal lesions.. https://doi.org/10.1016/s0379-0738(97)00113-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of isoflavones on lipids and bone turnover markers in menopausal women.

OBJECTIVES: The purpose of this analysis was to compare the effects of two dietary supplements derived from red clover to placebo on lipids and bone turnover markers in symptomatic menopausal women. METHODS: The study was a 12-week randomized, double-blind, placebo-controlled trial. Two hundred and fifty-two menopausal women ages 45-60 years experiencing > or =35 hot flashes per week were randomly assigned to Promensil (82 mg total isoflavones), Rimostil (57.2 mg total isoflavones), or placebo. Primary outcome measures were mean absolute changes for HDL-cholesterol, serum osteocalcin, and urinary N-telopeptide. Secondary outcome measures were mean changes of total cholesterol, LDL-cholesterol, the ratio of HDL- to LDL-cholesterol, and triglycerides. RESULTS: Ninety-eight percent of participants completed the 12-week protocol. Women taking Rimostil or Promensil compared to those taking placebo had greater mean increases in HDL-cholesterol; however, this change was small in magnitude (<2 mg/dl) and did not reach significance. There was a significant decrease in triglyceride levels among women taking Rimostil (14.4 mg/dl, P = 0.02) or Promensil (10.9 mg/dl, P = 0.05) compared to those taking placebo. The decrease was primarily among women with elevated baseline triglyceride levels (P for interaction = 0.009). There were no differences in mean changes of total cholesterol, LDL-cholesterol, or the ratio of HDL- to LDL-cholesterol among treatment groups. There were no statistically significant differences among treatment groups for bone turnover markers. CONCLUSIONS: Compared with placebo, both of the supplements containing isoflavones decrease levels of triglycerides in symptomatic menopausal women; however, this effect is small in magnitude.

Bone and Bones↗

High-throughput sample preparation procedures for the quantitation of a new bone integrin alpha(nu)beta(3) antagonist in human plasma and urine using liquid chromatography-tandem mass spectrometry.

High throughput LC-MS/MS assays to quantitate a new alpha(nu)beta(3) bone integrin antagonist (I) in human plasma and urine have been developed using instruments programmed to automate sample preparation procedures. Packard liquid handling system-MultiPROBE II EX was programmed for preparing calibration standards in control plasma and urine, acidifying all standards, quality control (QC), and clinical samples with necessary dilutions, and adding the internal standard to the acidified samples. TOMTEC Quadra 96 was programmed to perform the solid phase extraction (SPE) process on a 3M 96-well mixed phase cation standard density (MPC-SD) plate to isolate the analytes from the sample matrix. The extract collected from both types of matrices was directly injected into reversed-phase LC-MS/MS system with a Turbo Ion Spray (TIS) interface in the positive ionization mode. The plasma and urine assays have the calibration range of 0.5-1500 and 2-6000 ng/mL, respectively. Validation of the automated and the manual plasma assays showed that application of MultiPROBE II to sample preparation gave comparable accuracy and precision. Overall, the automated approaches with minimum manual intervention enhanced the throughput of sample preparation.

Bone and Bones↗