PubMed HealthSearch

PubMed · 9371964

Neuroselective current perception threshold quantitative sensory test: a re-evaluation.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P New. 1997. Neuroselective current perception threshold quantitative sensory test: a re-evaluation.. https://doi.org/10.1212/wnl.49.5.1482-a

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluating fluorescence sensitivity on flow cytometers: an overview.

The current paradigms for assessing fluorescence sensitivity on flow cytometers do not provide an adequate assessment of an instrument's ability to detect and measure weak fluorescence on stained particles. The capability to resolve dimly stained populations depends on two factors: the background noise (B), and the efficiency (Q) with which the fluorescence from the fluorochrome molecules are converted to photoelectrons. Any single statistical measure of fluorescence histogram distributions will be unable to uniquely characterize an instrument. Therefore, neither of the routinely used methods (detection threshold and delta channel) measure sensitivity completely and unambiguously. We show the limitations of these methods and propose that instrument sensitivity be characterized in terms of both background noise and detection efficiency in order to determine better the capability to detect and resolve weakly fluorescent particles.

Evaluation Studies as Topic

A set of van der Waals and coulombic radii of protein atoms for molecular and solvent-accessible surface calculation, packing evaluation, and docking.

We analyze the contact distance distributions between nonbonded atoms in known protein structures. A complete set of van der Waals (VDW) radii for 24 protein atom types and for crystal-bound water is derived from the contact distance distributions of these atoms with a selected group of apolar atoms. In addition, a set of Coulombic radii for polar atoms is derived from their contacts with water. The contact distance distributions and the two sets of radii are derived in a systematic and self-consistent manner using an iterative procedure. The Coulombic radii for polar atoms are, on average, 0.18 A smaller than their VDW radii. The VDW radius of water is 1.7 A, which is 0.3 A larger than its Coulombic radius. We show that both the VDW and the Coulombic radii of polar atoms are needed in calculating the molecular and solvent-accessible surfaces of proteins. The VDW radii are needed to generate the apolar portions of the surface and the Coulombic radii for the polar portions. The fact that polar atoms have two apparent sizes implies that a hydrophobic cavity has to be larger than a polar cavity in order to accommodate the same number of water molecules. Most surface area calculations have used only one radius for each polar atom. As a result, unreal cavities, grooves, or pockets may be generated if the Coulombic radii of polar atoms are used. On the other hand, if the VDW radii of polar atoms are used, the details of the polar regions of the surface may be lost. The accuracy of the molecular and the solvent-accessible surfaces of proteins can be improved if the radii of polar atoms are allowed to change depending on the nature of their contacting neighbors. The surface of a protein at a protein-protein interface differs from that in solution in that it has to be generated using at least two kinds of probes, one representing a typical apolar atom and the other a typical polar atom. This observation has important implications for docking, which relies on surface complementarity at the interface.

Evaluation Studies as Topic