PubMed · 937391
Automatic balance for fetal weight studies.
Abstract
An automatic balance was constructed of aluminum sheet, miniature ball bearings, and a strain gauge. The balance was capable of measuring 1 to 4 kg. with an accuracy of +/- 0.5 Gm. and a 95 per cent response time of less than 0.3 seconds. Fetuses of term ewes were exteriorized and weighed continuously for up to 3 hours. Rapid depletion of the ewe's blood volume led to a 10 to 24 per cent increase in estimated fetal blood volume. Fetal weight loss occurred regularly during reversible occlusion of the umbilical veins.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
R M Abrams, J F Clapp, D Caton, H T Hammel. 1976-07-01. Automatic balance for fetal weight studies.. https://doi.org/10.1016/0002-9378(76)90789-4