PubMed HealthSearch

PubMed · 9379247

List-mode likelihood.

Abstract

As photon-counting imaging systems become more complex, there is a trend toward measuring more attributes of each individual event. In various imaging systems the attributes can include several position variables, time variables, and energies. If more than about four attributes are measured for each event, it is not practical to record the data in an image matrix. Instead it is more efficient to use a simple list where every attribute is stored for every event. It is the purpose of this paper to discuss the concept of likelihood for such list-mode data. We present expressions for list-mode likelihood with an arbitrary number of attributes per photon and for both preset counts and preset time. Maximization of this likelihood can lead to a practical reconstruction algorithm with list-mode data, but that aspect is covered in a separate paper [IEEE Trans. Med. Imaging (to be published)]. An expression for lesion detectability for list-mode data is also derived and compared with the corresponding expression for conventional binned data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H H Barrett, T White, L C Parra. 1997. List-mode likelihood.. https://doi.org/10.1364/josaa.14.002914

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A quality assurance phantom for three-dimensional radiation treatment planning.

PURPOSE: Three-dimensional (3D) radiation treatment planning is facilitated through the use of computerized radiation treatment planning systems (RTPSs) and CT simulators (CT-sims). Quality assurance (QA) of these systems is necessary for ensuring that they fulfill their potential. However, comprehensive tools for the systematic QA of these systems have not been developed. We present a phantom that facilitates the evaluation of a large number of nondosimetric functions. These include CT image acquisition and transfer, graphical displays of 3D radiation beams, multiplanar CT image reconstructions, digitally reconstructed radiographs, the representation and manipulation of contoured patient anatomy, dose volume histograms, and the conversion of CT numbers to relative electron densities. METHODS AND MATERIALS: A phantom was constructed which contains materials and geometries that are appropriate for the routine QA of the features described above. The anatomy of the phantom is used as a standard against which the performance of the 3D-RTPS or CT-sim is evaluated. The phantom was used to evaluate three different 3D-RTPSs and a CT-sim at four institutions. RESULTS: Using this phantom, clinically significant errors and limitations in commercially available 3D treatment planning software were discovered. No errors were discovered in the beam display or image reconstructions in the systems examined. Problems were found in the anatomy display, automatic tools, and the CT number to relative electron density conversion data used in some of the systems. CONCLUSION: This phantom is a unique tool designed explicitly for the QA of 3D treatment planning software. Errors and limitations discovered through its use indicate that the QA of commercial treatment planning software is necessary, and that this phantom is an effective device for this task.

Image Processing, Computer-Assisted

A method for determining B1 field inhomogeneity. Are the biases assumed in heteronuclear relaxation experiments usually underestimated?

We describe a method allowing the determination of the effective B1 field amplitude distribution in a high-resolution NMR spectrometer. This method which can be adapted to almost any sequence, essentially consists of a mutation followed by a purging B0 gradient pulse. Experimental results obtained with this approach are described in homonuclear and heteronuclear cases. The experimental distributions are used to estimate the biases induced by B1 inhomogeneity, as well as the loss of RF power on heteronuclear transverse self-relaxation rate determination. In this type of measurement, the experimental biases induced on the intensities can be as large as 5% for long mixing times.

Image Processing, Computer-Assisted

J-multiplied HSQC (MJ-HSQC): a new method for measuring 3J(HNHalpha) couplings in 15N-labeled proteins.

A new method for the measurement of homonuclear 3J(HNHalpha) coupling constants in 15N-labeled small proteins is described. The method is based on a modified sensitivity enhanced HSQC experiment, where the 3J(HNHalpha) couplings are multiplied in the f1-dimension. The J-multiplication of homonuclear 3J(HNHalpha) couplings is based on simultaneous incrementation of 15N chemical shift and homonuclear coupling evolution periods. The time increment for the homonuclear coupling evolution period is chosen to be a suitable multiple (2N x t1) of the corresponding increment for 15N-shift evolution. This results in the splitting of the HSQC correlation in the f1-dimension by 2N x 3J(HNHalpha). Because the pulse sequence has good sensitivity and water suppression properties, it is particularly useful for natural abundance samples.

Image Processing, Computer-Assisted