PubMed HealthSearch

PubMed · 9384624

Modelling accelerated degradation data using Wiener diffusion with a time scale transformation.

Abstract

Engineering degradation tests allow industry to assess the potential life span of long-life products that do not fail readily under accelerated conditions in life tests. A general statistical model is presented here for performance degradation of an item of equipment. The degradation process in the model is taken to be a Wiener diffusion process with a time scale transformation. The model incorporates Arrhenius extrapolation for high stress testing. The lifetime of an item is defined as the time until performance deteriorates to a specified failure threshold. The model can be used to predict the lifetime of an item or the extent of degradation of an item at a specified future time. Inference methods for the model parameters, based on accelerated degradation test data, are presented. The model and inference methods are illustrated with a case application involving self-regulating heating cables. The paper also discusses a number of practical issues encountered in applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G A Whitmore, F Schenkelberg. 1997. Modelling accelerated degradation data using Wiener diffusion with a time scale transformation.. https://doi.org/10.1023/a%3A1009664101413

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

In vitro assessment of back pressure on ventriculoperitoneal shunt valves. Is laparoscopy safe?

BACKGROUND: Whereas there are case reports of laparoscopy in patients with ventriculoperitoneal shunts, there are no studies assessing the potential failure of shunt valves with the increased intra-abdominal pressure of laparoscopy. This study aims to assess this factor. METHODS: An in vitro model was used to assess the potential for retrograde failure of ventriculoperitoneal shunt valves in a commonly used shunt. Nine shunts were subjected to graded increases in back pressure and observed for retrograde valve leak. RESULTS: None of the shunts tested showed any signs of leak associated with the increased back pressure. However, disruption of shunt seals was noted in seven of the nine shunts, occurring at the minimal pressure of 80 mmHg. CONCLUSIONS: There appears to be minimal risk of retrograde failure of the valve system in the ventriculoperitoneal shunt tested. However, tests on different types of ventriculoperitoneal shunts would be needed to confirm these results if laparoscopy is to be considered safe in patients with ventriculoperitoneal shunts in situ.

Equipment Failure

[Daily medical device surveillance].

In France the manufacturer, the user of a medical device and all those informed of an event or a risk for an event caused by the device and resulting in death or the deterioration of the health status of a patient must declare the event without delay to the appropriate administrative authority. The witness of the event informs either the local correspondent for materiovigilance, when available, or the ministry directly. A major objective of the local correspondent is to act as a filter and to select among the declarations of events those to be transmitted without delay or quarterly to the ministry, and those to be registered only locally. Within 48 hours the ministry: a) returns an acknowledgement with instructions how to proceed with the involved device; b) communicates the declaration to the chairman of the ad hoc subcommission; c) informs the manufacturer of the device. The chairman decides on the degree severity (major event requiring an immediate investigation, event requiring an investigation, event to be entered in a follow-up programme). In the first two cases an investigation is undertaken by one or several members of the subcommission in co-operation with the manufacturer and the declarant of the event. Conservative measures can be undertaken to prevent the re-occurrence of an event either with the involved and/or with similar devices and to facilitate the investigation.

Equipment Failure