PubMed Health⌕ Search

PubMed · 9413613

Effective one/two step purification of various materials by solid-phase extraction.

Abstract

Simple one/two step purification procedures based on the solid-phase extraction technique were effectively exploited to clean up radiolabelled drugs represented by dihydrochloride of [6-3H]-stobadine and hydrochloride of [4-3H]-pentacaine, derivatization agents such as 4-nitrobenzoyl chloride or 3,5-dinitrobenzoyl chloride, as well as the aqueous phosphate or triethylamine acetate buffer solutions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Soltés, B Sébille. Effective one/two step purification of various materials by solid-phase extraction.. https://doi.org/10.1002/(sici)1099-0801(199711)11%3A6%3C348%3A%3Aaid-bmc689%3E3.3.co%3B2-w

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Repaglinide].

Explore the source record for details and available documents.

Carbamates↗

Determination of carbamate, urea, and thiourea pesticides and herbicides in water.

Microbore liquid chromatography and positive ion electrospray mass spectrometry are applied to the determination of 16 carbamate, urea, and thiourea pesticides and herbicides in water. The electrospray mass spectra of the analytes were measured and are discussed and mobile-phase matrix effects were evaluated. Analyte positive ion abundances are generally inversely related to the concentration of acetic acid in the acetonitrile-water mobile phase in the range of 0.001-0.1% (v/v) acetic acid. Using an internal standard for quantitative analyses and no acid in the mobile phase, retention time precision, peak width precision, concentration measurement precision, mean recoveries, and instrument detection limits were determined in reagent water. The 16 analytes were also measured in fortified environmental water samples from a recreational lake, a groundwater well, a cistern, a farm pond, and drinking water. These measurements were at 5 ng/mL of each analyte, which is within the range expected for environmental pesticide and herbicide contaminants. The analytes were separated from the environmental water matrixes with an on-line extraction and concentration to provide rapid sample analyses without a slow off-line liquid-liquid or liquid-solid-liquid extraction and extract concentration. Recoveries of 12 of the analytes from 4 environmental water samples were in the range of 75-124% with relative standard deviations in the range of 11-16%.

Carbamates↗