PubMed HealthSearch

PubMed · 9430342

Methods for assessing accuracy and reliability in functional MRI.

Abstract

In this paper, methods for assessing the accuracy and the reliability of functional magnetic resonance imaging techniques are presented. First, a modified receiver operating characteristic analysis is described for evaluating the accuracy of fMRI studies. With this modified approach, the true positives or the activated pixels are estimated based on highly averaged experimental data acquired with the same stimulation/task. Unlike ROC analysis based on simulated activation data, the present approach can be applied to experimentally acquired data without simplifying the activation related changes. To assess the reliability of fMRI studies, the kappa statistic was adopted for evaluating the overall agreement of functional activation maps from repeated experiments in individual subjects. To demonstrate the utility of these techniques, both the ROC analysis and the reliability assessment were applied to quantitatively evaluate the improvement in accuracy and reliability of a retrospective technique for physiological noise reduction in fMRI.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T H Le, X Hu. Methods for assessing accuracy and reliability in functional MRI.. https://doi.org/10.1002/(sici)1099-1492(199706%2F08)10%3A4%2F5%3C160%3A%3Aaid-nbm458%3E3.0.co%3B2-a

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultra-high-field 7T MRI reveals neural abnormalities of attention networks in relation to cognitive impairment in hypertension.

Hypertension is a significant risk factor for cognitive impairment (CI), yet the corresponding neural network abnormalities remain underexplored. In this study, we examined the associations among global and domain-specific cognitive dysfunction, neuroimaging measures, and blood pressure in a subgroup of hypertensive patients with CI (N = 41) from a randomized controlled trial who underwent ultra-high-field 7 T MRI. Structural atrophy related to CI was localized to regions overlapping the attention networks. Both whole-brain and within-network dysfunction of the attention networks were associated with worse global cognitive performance. Notably, hyperconnectivity within key attention network hubs, including the right anterior insula and posterior intraparietal sulcus, was associated with declined processing speed in hypertensive patients, mediating the association between pulse pressure and processing speed. These findings provide new insights into the neural pathophysiology of hypertension-related CI and suggest potential network-based targets for intervention.

Magnetic Resonance Imaging

Magnetic fields mapping with the phase reference method.

A simple method for imaging the magnetic field produced by arbitrary current distributions is presented. The method is based on the use of a phase reference image and can be easily adapted to any standard magnetic resonance imaging scanner. Examples are given to application to gradient coil characterization and quantitative field measurements.

Magnetic Resonance Imaging

Sound generation in gradient coil structures for MRI.

When supporting plates of plastic material are subjected to alternating transverse Lorentz forces while in a strong magnetic field normal to the plate surface, compressional waves within the solid produce a modulation of the plate surface that launches an acoustic wave in air along the magnetic field axis. We have extended our previous theory describing this process to include a detailed description of the formation of an acoustic interference pattern in air described by Fraunhofer diffraction at a distance from the plate surface. The extended theory predicts that the observed acoustic signal midpoint and normal to the plate surface gives a variation with frequency in approximate agreement with our previous measurements. The acoustic output off axis shows acoustic blazing that produces two main diffraction peaks with a splitting inversely proportional to the velocity of sound in the plate material. The new results could have important ramifications for the minimization of sound output in gradient coil design for MRI. A new arrangement of coils is proposed to ameliorate the acoustic output problem centrally and normal to the plate by extending the frequency response of the supporting plates to much higher frequencies. Also presented are estimates of the compressional wave velocities deduced from frequency response data recorded at the center-point of a number of different plates.

Magnetic Resonance Imaging