PubMed HealthSearch

PubMed · 9433319

Joint replacement "camp".

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V Conroy. 1996-12-16. Joint replacement "camp".. https://pubmed.ncbi.nlm.nih.gov/9433319/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dosimetry of hip irradiation for the prevention of heterotopic bone formation after arthroplasty.

PURPOSE: The dosimetry of hip irradiation for the prevention of heterotopic bone formation following arthroplasty is complicated by the use of custom shielding in the treatment portal, and the fact that irradiation is usually required during a 48 hour period following surgery. Both the machine output and depth dose factors of the resulting fields are modified by the presence of the shielding blocks. A simplified dosimetric approach, based on correction factors for both the output and depth dose as a function of field geometry is presented for various megavoltage energy beams. MATERIALS AND METHODS: Measurements of relative dose factors (RDF) and percentage depth dose (PDD) were carried out for different combinations of field size, block size and separation between adjacent blocks. Both RDF and PDD measurements were made in a water phantom. Ratios of RDF and PDD were obtained by dividing individual measurements or curves by the corresponding values for the open field (i.e., without blocks). The average values of these ratios constitute the correction factors to be applied for a given MU or treatment time calculation. RESULTS: Extensive RDF and PDD measurements reveal that for the field and block dimensions of interest the correction factors for RDF can be parameterized as a function of separation between two adjacent blocks and beam energy alone and the depth correction factors are additionally only a function of depth. The correction factors for depth dose are equally valid for fixed source-skin distance techniques (that use PDD) and fixed source-axis distance techniques (that use TMR). CONCLUSION: A simple model for the calculation of output in hip irradiation is presented for the situation where the use of computer-based algorithms may not be practical. The model accurately predicts the RDF of the treatment portal to within 2% and the PDD to within 2% for the range of field sizes, block sizes, block gaps and beam energies of interest ignoring other variables.

Arthroplasty, Replacement, Hip

[Salvaged femoral heads banked for re-use. Excellent bone replacement in revision of prosthetic surgery].

Morsellized and compacted femoral heads salvaged after hip arthroplasty constitute an excellent bone replacement material. Access to this material has substantially improved prognosis following replacement of loosened prostheses, a finding contrary to previous experience with uncompacted bone grafts and for which only hypothetical explanations are available. Although bank bone is a material without manifest value beyond its material properties, it is sometimes referred to as a transplant, a usage that has resulted in its occasional use under the misapprehension that it will promote bone repair, which may cause problems. Otherwise, bank bone is more or less innocuous and is not associated with a greater risk of viral infection transmission than is blood transfusion. The article provides a review of the biological effects to be expected of bank bone implants, how the risk of infection can be avoided, and which indications are appropriate.

Arthroplasty, Replacement, Hip

Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.

Osteolysis induced by ultra high molecular weight polyethylene wear debris is one of the primary factors limiting the lifespan of total hip replacements. Crosslinking polyethylene is known to improve its wear resistance in certain industrial applications, and crosslinked polyethylene acetabular cups have shown improved wear resistance in two clinical studies. In the present study, crosslinked polyethylene cups were produced by two methods. Chemically crosslinked cups were produced by mixing a peroxide with ultra high molecular weight polyethylene powder and then molding the cups directly to shape. Radiation-crosslinked cups were produced by exposing conventional extruded ultra high molecular weight polyethylene bar stock to gamma radiation at various doses from 3.3 to 100 Mrad (1 Mrad = 10 kGy), remelting the bars to extinguish residual free radicals (i.e., to minimize long-term oxidation), and then machining the cups by conventional techniques. In hip-joint simulator tests lasting as long as 5 million cycles, both types of cross-linked cups exhibited dramatically improved resistance to wear. Artificial aging of the cups by heating for 30 days in air at 80 degrees C induced oxidation of the chemically crosslinked cups. However, a chemically crosslinked cup that was aged 2.7 years at room temperature had very little oxidation. Thus, whether substantial oxidation of chemically crosslinked polyethylene would occur at body temperature remains unclear. The radiation-crosslinked remelted cups exhibited excellent resistance to oxidation. Because crosslinking can reduce the ultimate tensile strength, fatigue strength, and elongation to failure of ultra high molecular weight polyethylene, the optimal crosslinking dose provides a balance between these physical properties and the wear resistance of the implant and might substantially reduce the incidence of wear-induced osteolysis with total hip replacements.

Arthroplasty, Replacement, Hip