Abstract

The problem of automatically tuning and matching a probe is considered, and attention is drawn to the main cause of difficulty: the interaction of tuning and matching mechanisms. The use of a doubly resonant, inductively coupled probe is therefore advocated, for to first order, tuning, and matching are then orthogonal for small perturbations. It is shown that when such a probe is equipped with negative feedback control of tuning and matching elements, driven by error signals derived from a bridge and the NMR spectrometer, stable and rapid automatic tuning and matching are achieved. The importance of approximately correct phasing of the error signals is emphasized, but the restriction of having to have specific cable lengths to achieve this task is removed. The effects of small errors of phasing are then considered and shown to be unimportant for the chosen probe, in contrast to the situation for other, nonorthogonal probe types. Suggestions for orthogonalization of two common capacitively coupled probe designs are made, and a practical instrument design is then given that, with the addition of external components, can also be used if the NMR receiver cannot be pressed into service.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Hwang, D I Hoult. 1998. Automatic probe tuning and matching.. https://doi.org/10.1002/mrm.1910390208

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Steam sterilizable probes for dissolved oxygen measurement. Reprinted from Biotechnology and Bioengineering, Vol. VI, Issue 4, Pages 457-468 (1964).

Steam-sterilizable membrane probes for monitoring the dissolved oxygen level in fermentors, or the oxygen content of gas streams, are described. The probes have a silver cathode, a lead anode, and an acetate buffer as an electrolyte. The membrane is Teflon. The current output of the probes in the absence of oxygen is negligible.

Equipment Design

Performance-based standards: safety instrumented functions and safety integrity levels.

This paper discusses two international performance-based standards, ANSI/ISA S84.01 and IEC d61508 and the requirements they place upon companies that rely on electrical, electronic and programmable electronic systems to perform safety functions. Performance-based regulations are also discussed and common safety elements between the standards and regulations are identified. Several risk analysis techniques that can be used to comply with the aforementioned requirements are discussed and a simple example is used to illustrate the use, advantages and disadvantages of the techniques. The evaluation of safety integrity level (SIL) of the Safety Instrumented System (SIS) in terms of the probability to fail to function is outside the scope of this paper.

Equipment Design