PubMed Health⌕ Search

PubMed · 9474307

A fully automated comparative microaneurysm digital detection system.

Abstract

A fully automated digital image processing system, which provides an objective and repeatable way to quantify microaneurysms in digitised fluorescein angiograms, has been developed. The automated computer processing includes registration of same-eye retinal images for serial studies, cutting of regions-of-interest centred on the fovea, the detection of microaneurysms and the comparison of serial images for microaneurysm turnover. The microaneurysm detector was trained against a database of 68 images of patients with diabetes containing 394 true microaneurysms, as identified by an ophthalmologist. The microaneurysm detector achieved 82% sensitivity with 2.0 false-positives per image. An independent test set, comprising 20 images containing 297 true microaneurysms, was used to compare the microaneurysm detector with clinicians. The microaneurysm detector achieved a sensitivity of 82% for 5.7 false-positives per image, whereas the clinician receiver-operator-characteristic (ROC) curve gives 3.2 false-positives per image at a sensitivity of 82%. It is concluded that the computer system can reliably detect microaneurysms. The advantages of the computer system include objectivity, repeatability, speed and full automation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Cree, J A Olson, K C McHardy, P F Sharp, J V Forrester. 1997. A fully automated comparative microaneurysm digital detection system.. https://doi.org/10.1038/eye.1997.166

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Mechanistic insights into Claudin-14 dysfunction implicated in veins of Galen malformation.

Claudin-14 (CLDN14) is a key component of tight junctions (TJs) critical for maintaining paracellular barrier function. Variants of CLDN14 have been linked to Vein of Galen malformations (VOGMs), a rare cerebrovascular disorder; however, the molecular mechanisms underlying their pathogenicity remain unknown. Here, we investigate the mechanistic effects of two VOGM-associated mutations, A113P and V143M, using reinforcement-learning driven enhanced sampling molecular dynamics simulations combined with DiffNets-based deep learning and independent trajectory-wide structural analyses. Our analysis reveals that A113P induces broader structural disruption of CLDN14, perturbing paracellular sealing, pore symmetry, and inter-protomer communication, whereas V143M induces structural rearrangements centred around TM3 and the TM3-ECL2 region. In both cases, mutation-specific alterations are observed in structural stability and interfacial organization across oligomeric assemblies. Notably, these effects are qualitatively consistent across different modelled architectures, despite variability in local responses. In the absence of experimentally resolved structures, the structural perturbations reported here provide a mechanistic understanding of how VOGM-associated variants may influence CLDN14 structure and dynamics.

Aneurysm↗