PubMed Health⌕ Search

PubMed · 9479302

Endogenous cryptococcal endophthalmitis.

Abstract

BACKGROUND: Occurrence of cryptococcal endophthalmitis is rare and commonly is associated with widespread disseminated diseases. The authors report here a well-documented case of endogenous cryptococcal endophthalmitis without the preceding meningeal infection. METHODS: A 45-year-old female with a history of long-term use of systemic corticosteroid and cytotoxic drugs for systemic lupus erythematosus suffered from progressive visual loss in her left eye over 1 month. Large exudative retinal detachment and severe vitreous infiltration were observed. RESULTS: Histopathologic study of the retinal biopsy specimen established the diagnosis of cryptococcal endophthalmitis. Subsequent positive histopathologic study of the aspiration vitreous smear and epiretinal membrane confirmed the recurrence and persistence of the disease over 4 months after the initial presentation. Systemic amphotericin B-fluconazole and two doses of intravitreous amphotericin B injection eliminated the infection successfully. CONCLUSION: The authors report here a well-documented case of cryptococcal endophthalmitis and present the serial clinical and histopathologic pictures. The importance of retinal biopsy in diagnosis and the combined form of antifungal treatment also are shown.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S J Sheu, Y C Chen, N W Kuo, J H Wang, C J Chen. 1998. Endogenous cryptococcal endophthalmitis.. https://doi.org/10.1016/s0161-6420(98)93679-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Multi-Omics Analysis of Experimentally Evolved Candida auris Isolates Reveals Modulation of Sterols, Sphingolipids, and Oxidative Stress in Acquired Amphotericin B Resistance.

Clinical isolates of Candida auris show a high prevalence of resistance to Amphotericin B (AmB)-an uncommon trait in most Candida species. Alterations in ergosterol biosynthesis can contribute to acquired AmB resistance in C. auris laboratory strains but are rarely seen in clinical isolates. In this study, we experimentally evolved two drug-susceptible Clade II isolates of C. auris to develop AmB resistance. The evolved strains displayed a four to eight fold increase in MIC50 compared to the parental cells. We analyzed changes in their karyotype, genome, lipidome, and transcriptome associated with this acquired resistance. In one lineage, AOX2 was upregulated, and its deletion reversed the AmB resistance phenotype. The aox2Δ mutant also failed to evolve AmB resistance under experimental conditions. In the same lineage, restoring the UPC2 S332R and RTG3 S101T mutations to the wild-type allele restored AmB susceptibility. In another lineage, the ergosterol and sphingolipid pathways were observed to play a critical role, and upregulation of the ERG genes elevated the total sterol content, while significant downregulation of HSX11 (glucosylceramide synthase) resulted in lower levels of glucosylceramides. To our knowledge, this study is the first to show that AmB resistance in C. auris can be acquired through mechanisms both dependent on or independent of sterol content modulation, highlighting Aox2 and Upc2 as key regulators of amphotericin resistance.

Amphotericin B↗

Cholesterol overload promotes morphogenesis of a Niemann-Pick C (NPC)-like compartment independent of inhibition of NPC1 or HE1/NPC2 function.

Cholesterol accumulation in an aberrant endosomal/lysosomal compartment is the hallmark of Niemann-Pick type C (NPC) disease. To gain insight into the etiology of the NPC compartment, we studied a novel Chinese hamster ovary cell mutant that was identified through a genetic screen and phenocopies the NPC1 mutation. We show that the M87 mutant harbors a mutation in a gene distinct from the NPC1 and HE1/NPC2 disease genes. M87 cells have increased total cellular cholesterol with accumulation in an aberrant compartment that contains LAMP-1, LAMP-2, and NPC1, but not CI-MPR, similar to the cholesterol-rich compartment in NPC mutant cells. We demonstrate that low-density lipoprotein receptor activity is increased 3-fold in the M87 mutant, and likely contributes to accumulation of excess cholesterol. In contrast to NPC1-null cells, the M87 mutant exhibits normal rates of delivery of endosomal cholesterol to the endoplasmic reticulum and to the plasma membrane. The preserved late endosomal function in the M87 mutant is associated with the presence of NPC1-containing multivesicular late endosomes and supports a role for these multivesicular late endosomes in the sorting and distribution of cholesterol. Our findings implicate cholesterol overload in the formation of an NPC-like compartment that is independent of inhibition of NPC1 or HE1/NPC2 function.

Amphotericin B↗

Determination of amphotericin B, liposomal amphotericin B, and amphotericin B colloidal dispersion in plasma by high-performance liquid chromatography.

Amphotericin B is a potent polyene antifungal drug for intravenous treatment of severe infections. It is used as amphotericin B-deoxycholate and in order to reduce amphotericin B toxicity as lipid-formulated complex (liposomal or colloidal dispersion). A sensitive and specific analytical method is presented for the separation of lipid-complexed and plasma protein-bound amphotericin B in human heparinized plasma. This separation, which is required for pharmacokinetic studies, is achieved by solid-phase extraction (SPE) via Bond Elut C18. The protein-bound amphotericin B has a higher affinity to the SPE material and is therefore retained, whereas the lipid-complexed amphotericin B is eluted in the first step. The recovery of the SPE was >75% for high concentrations and >95% for low concentrations. Quantification was performed by reversed-phase HPLC using a LiChrosorb-RP-8 column, UV detection (lambda=405 nm) and a mixture of acetonitrile-methanol-0.010 M NaH2PO4 buffer (41:10:49, v/v) as mobile phase. The retention time for amphotericin B under the given conditions was 6.7 min. The calibration curves were found to be linear (r > or = 0.999) in two different ranges (5.0-0.50 microg/ml and 0.50-0.005 microg/ml). Intra- and inter-day precision and accuracy fulfilled the international requirements. No interference from other drugs (typical broad medication for intensive-care patients) or common plasma components was detected in >400 samples analyzed.

Amphotericin B↗