PubMed Health⌕ Search

PubMed · 9499587

Dynamic contrast perception assessed by pattern masking.

Abstract

The perceived contrast of a pulsed grating varies markedly with the exposure duration and spatial frequency of the grating. We studied dynamic changes in perceived grating contrast with a pattern-masking paradigm. We measured masking of a brief, localized test pattern (a D6 stimulus, 30 ms in duration) by fixed-contrast cosine grating patterns of varying duration (50-500 ms). The cosine mask pattern had spatial frequency of either 1 or 6 cycles per degree (cpd) at a contrast of 0.3. The D6 test pattern was centered on a light bar of the mask and was either positive peak contrast (same-polarity test and mask) or negative peak contrast (opposite-polarity test and mask). In Experiment 1, the test and mask had simultaneous onset. With a 6-cpd mask, the same-polarity test-threshold elevation versus mask-duration function increases monotonically. For a 1-cpd mask, the same-polarity threshold-mask-duration function is nonmonotonic, with peak masking effect produced by a grating pulse of 80-100 ms. These masking effects are closely congruent with known dynamic contrast effects. With negative tests, masking-duration functions are elevated from same-polarity functions and are essentially similar in shape for 1- and 6-cpd masks. The elevated thresholds suggest inhibitory interaction between ON and OFF pathways, with a similar time course across spatial frequency. In Experiment 2, the D6 test was delayed from mask onset by 33 ms. Positive contrasts only were employed. For 1-cpd stimuli, the delay of test greatly reduced masking at all mask durations and eliminated the nonmonotonic function. This suggests that for low-spatial-frequency patterns, perceived contrast is determined by an early peak component of the neural response. But for 6-cpd stimuli, masking of the delayed test was somewhat greater at all mask durations, consistent with a gradually increasing underlying neural response to the grating. Finally, in Experiment 3, same-polarity masking effects at both spatial frequencies were replicated with negative-contrast test and mask (OFF pathway mediation). This indicates that the ON and OFF pathways have similar response dynamics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R W Bowen, H de Ridder. 1998. Dynamic contrast perception assessed by pattern masking.. https://doi.org/10.1364/josaa.15.000570

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

High refractive index substrates for fluorescence microscopy of biological interfaces with high z contrast.

Total internal reflection fluorescence microscopy is widely used to confine the excitation of a complex fluorescent sample very close to the material on which it is supported. By working with high refractive index solid supports, it is possible to confine even further the evanescent field, and by varying the angle of incidence, to obtain quantitative information on the distance of the fluorescent object from the surface. We report the fabrication of hybrid surfaces consisting of nm layers of SiO(2) on lithium niobate (LiNbO(3), n = 2.3). Supported lipid bilayer membranes can be assembled and patterned on these hybrid surfaces as on conventional glass. By varying the angle of incidence of the excitation light, we are able to obtain fluorescent contrast between 40-nm fluorescent beads tethered to a supported bilayer and fluorescently labeled protein printed on the surface, which differ in vertical position by only tens of nm. Preliminary experiments that test theoretical models for the fluorescence-collection factor near a high refractive index surface are presented, and this factor is incorporated into a semiquantitative model used to predict the contrast of the 40-nm bead/protein system. These results demonstrate that it should be possible to profile the vertical location of fluorophores on the nm distance scale in real time, opening the possibility of many experiments at the interface between supported membranes and living cells. Improvements in materials and optical techniques are outlined.

Contrast Sensitivity↗

Intrasaccadic perception.

Mammalian vision has a lowpass frequency characteristic that filters out fast temporal oscillations. Thus, fast-drifting gratings cannot be detected with static eyes, but the same gratings can easily be detected by executing saccades. Because these gratings are invisible under fixation, they are useful for isolating and studying intrasaccadic perception, which is normally masked by presaccadic and postsaccadic perception. We have conducted a number of psychophysical studies using these stimuli, and here we report that intrasaccadic visual processing allows for motion perception, that gratings drifting in the direction of a saccade are perceived as having more contrast than the same gratings drifting in the opposite direction, and that intrasaccadic contrast perception has sufficient grain to allow psychophysical matching of the perceived contrast of gratings drifting in opposite directions. The conditions in which these phenomena occur disprove a recent hypothesis that intrasaccadic motion perception occurs for stimuli processed by the magnocellular system, and our results can be explained by assuming that the temporal lowpass characteristic that accounts for flicker fusion phenomena under vision with static eyes is also operative during saccades.

Contrast Sensitivity↗