Quantitative video microscopy.

Abstract

Obviously there are many variations and embellishments on the topic of quantitating your image. I have tried here to offer you a very practical guide which highlights some of the critical issues paying particular attention to problems which can prevent or compromise your success. These include: errors due to aspect ratio, use of automatic camera settings, improper setting of dynamic range, and use of integer arithmetic. Further information can be found in several other chapters in this volume as well as in the references below. Additionally you shouldn't overlook the technical manuals which come with your video systems. The field of video microscopy has evolved as a cooperative effort between academia and industry. As a result you will find that many of the technical support personnel from microscope, video, and image processing companies are well versed on the issue of video imaging in biology and are more than willing to assist you.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D E Wolf. 1998. Quantitative video microscopy.. https://pubmed.ncbi.nlm.nih.gov/9500135/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Shape-based grey-level image interpolation.

The three-dimensional (3D) object data obtained from a CT scanner usually have unequal sampling frequencies in the x-, y- and z-directions. Generally, the 3D data are first interpolated between slices to obtain isotropic resolution, reconstructed, then operated on using object extraction and display algorithms. The traditional grey-level interpolation introduces a layer of intermediate substance and is not suitable for objects that are very different from the opposite background. The shape-based interpolation method transfers a pixel location to a parameter related to the object shape and the interpolation is performed on that parameter. This process is able to achieve a better interpolation but its application is limited to binary images only. In this paper, we present an improved shape-based interpolation method for grey-level images. The new method uses a polygon to approximate the object shape and performs the interpolation using polygon vertices as references. The binary images representing the shape of the object were first generated via image segmentation on the source images. The target object binary image was then created using regular shape-based interpolation. The polygon enclosing the object for each slice can be generated from the shape of that slice. We determined the relative location in the source slices of each pixel inside the target polygon using the vertices of a polygon as the reference. The target slice grey-level was interpolated from the corresponding source image pixels. The image quality of this interpolation method is better and the mean squared difference is smaller than with traditional grey-level interpolation.

Image Enhancement

New low-contrast resolution phantoms for computed tomography.

Computed tomography (CT) has been established as a major imaging modality in diagnostic radiology. Accordingly, acceptance testing and quality control of CT scanners is of great importance. While most procedures and phantoms for testing are widely accepted, there is still discussion and uncertainty about low-contrast (LC) sensitivity. In our opinion this unsatisfactory situation is caused at least in part by the lack of suitable phantoms for LC resolution measurements. We investigated the commonly used phantoms for LC detectability, the Catphan, and for LC resolution, the ATS phantom. While the Catphan showed stable object contrasts, the ATS phantom's measured contrast exhibited a strong dependence on temperature and x-ray quality. Based on newly developed polyurethane resin materials, we designed and tested a LC resolution phantom with several different contrast steps. The object contrasts showed no dependence on temperature and beam quality. The new LC resolution phantom proved to be very suitable for measuring a scanner's low-contrast sensitivity in the image plane, one of the most important image quality parameters. To assess LC resolution in three dimensions we designed an additional phantom with rows of spherical objects. A first prototype was evaluated in a multicenter study. The setup proved to be very helpful to quantify the in-plane and axial LC sensitivity of spiral CT scan modes.

Image Enhancement

Automated recognition of patterns characteristic of subcellular structures in fluorescence microscopy images.

Methods for numerical description and subsequent classification of cellular protein localization patterns are described. Images representing the localization patterns of 4 proteins and DNA were obtained using fluorescence microscopy and divided into distinct training and test sets. The images were processed to remove out-of-focus and background fluorescence and 2 sets of numeric features were generated: Zernike moments and Haralick texture features. These feature sets were used as inputs to either a classification tree or a neural network. Classifier performance (the average percent of each type of image correctly classified) on previously unseen images ranged from 63% for a classification tree using Zernike moments to 88% for a backpropagation neural network using a combination of features from the 2 feature sets. These results demonstrate the feasibility of applying pattern recognition methods to subcellular localization patterns, enabling sets of previously unseen images from a single class to be classified with an expected accuracy greater than 99%. This will provide not only a new automated way to describe proteins, based on localization rather than sequence, but also has potential application in the automation of microscope functions and in the field of gene discovery.

Image Enhancement