Inverse optimization: functional and physiological considerations related to the force-sharing problem.

Abstract

This paper is a review of the optimization techniques used for the solution of the force-sharing problem in biomechanics; that is, the distribution of the net joint moment to the force generating structures such as muscles and ligaments. The solution to this problem is achieved by the minimization (or maximization) of an objective function that includes the design variable (usually muscle forces) that are subject to certain constraints, and it is generally related to physiological or mechanical properties such as muscle stress, maximum force or moment, activation level, etc. The usual constraints require the sum of the exerted moments to be equal to the net joint moment and certain boundary conditions restrict the force solutions within physiologically acceptable limits. Linear optimization (objective and constraint functions are both linear relationships) has limited capabilities for the solution of the force sharing problem, although the use of appropriate constraints and physiologically realistic boundary conditions can improve the solution and lead to reasonable and functionally acceptable muscle force predictions. Nonlinear optimization provides more physiologically acceptable results, especially when the criteria used are related to the dynamics of the movement (e.g., instantaneous maximum force derived from muscle modeling based on length and velocity histories). The evaluation of predicted forces can be performed using direct measurements of forces (usually in animals), relationship with EMG patterns, comparisons with forces obtained from optimized forward dynamics, and by evaluating the results using analytical solutions of the optimal problem to highlight muscle synergism for example. Global objective functions are more restricting compared to local ones that are related to the specific objective of the movement at its different phases (e.g., maximize speed or minimize pain). In complex dynamic activities multiobjective optimization is likely to produce more realistic results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Tsirakos, V Baltzopoulos, R Bartlett. 1997. Inverse optimization: functional and physiological considerations related to the force-sharing problem.. https://doi.org/10.1615/critrevbiomedeng.v25.i4-5.20

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗