A continuous penalty function method for inverse treatment planning.

Abstract

Conventional inverse treatment planning attempts to calculate dose distributions that may not be feasible given the specified dose levels to various anatomical structures. A technique for inverse treatment planning has been developed that uses only target dose levels which are easily selectable to be feasible. A nonlinear constrained minimization problem is formulated to reflect the goal of sparing critical organs as much as possible while delivering a certain target dose within specified uniformity. The objective function is the squared dose delivered to critical organs. The constraints require the delivery of certain target dose within specified uniformity and non-negative pencil beam weights. A continuous penalty function method is introduced as a method for solving the large-scale constrained minimization problem. The performance of the continuous penalty function method is optimized by numerical investigation of few numerical integration schemes and a pair of weighting functions which influence the utility of the method. Clinical examples are presented that illustrate several features of the technique. The properties of the continuous penalty function method suggest that it may be a viable alternative to conventional inverse treatment planning.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D H Hristov, B G Fallone. 1998. A continuous penalty function method for inverse treatment planning.. https://doi.org/10.1118/1.598183

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New high-DQE imaging plate scanner using the reflected readout laser signal for noise corrections.

Imaging Plates (IPs) are in principle ideal electron detectors combining a large active layer area with a high sensitivity, linear dynamic range detection over 5 orders of magnitude. A moderate resolution and a decreasing detection quantum efficiency (DQE) for higher electron doses limit their use so far. The decrease of the DQE results from linear noise contributed by readout laser instabilities and inhomogeneities of the IP active layer. Here we present data on a new IP drum scanner prototype. This scanner combines twin channel amplification electronics with a new type of readout laser which allows a smaller readout focus and increased stability. The current nominal pixel size is 25 microm, and the measured modulation transfer function (MTF) indicates that further reduction of the scanning step size down to pixel sizes in the range of 12-15 microm should be possible. A unique feature of the new scanner is the simultaneous recording of the reflected readout laser light. The reflected light signal can be used for a posteriori alignment of repeated scans of one individual IP and for a correction of one part of the high spatial frequency noise contribution (reflected light correction). The posteriori alignment now allows an easy conventional gain normalization of the luminescence signal without using special markers on the IP. Both corrections lead to an increase of the DQE for high electron doses.

Biophysical Phenomena↗

Evaluation of scanners and CCD cameras for high-resolution TEM of protein crystals and single particles.

The modulation transfer function (MTF) and the geometric errors of two flatbed scanners, a slow-scan CCD (SSC) camera and film, have been measured and compared. The geometric errors of the SSC camera and film have been measured using diffraction spots from a lipid crystal. The SSC camera was shown to have the smallest geometric errors while film had the best MTF. Even though film had the best MTF, this is significantly reduced when scanning the film, so that the MTF of the film and scanner combined are comparable to the MTF of the SSC camera.

Biophysical Phenomena↗

Exit wave reconstructions using through focus series of HREM images.

The through focus exit wave reconstruction technique uses a series of high resolution electron microscopy images to reconstruct the complex electron wavefunction at the exit plane of the specimen. The feasibility of the through focus exit wave reconstruction method and its most important limitations are discussed. It is shown that-provided all aberrations of the microscope are well corrected for-a large improvement in the interpretability of the information can be obtained.