Abstract

In order to avoid the potential risk of a short refractory period and the inconvenience of the electronic blocking mechanism at the highest synchronous rate with the conventional atrial triggered pulse generator, two more functions have been added to the normal atrial triggered (VAT) pulse generator. First, it has been designed to be ventricular inhibited; second, a highest synchronous rate detector has been added. When the highest synchronous rate of about 140 is exceeded, the atrial signals are blocked and the frequency of the basic rate generator is increased to about 130. Two patients could hardly feel the change from atrial triggered pacing to ventricular inhibited stimulation, and both were able to work at higher loads with this type of pacing compared with the conventional atrial triggered pulse generator.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Pehrsson, J Lentell, M Levander-Lindgren, B Svensson. 1979. A new concept for atrial triggered pulse generators.. https://doi.org/10.1111/j.1540-8159.1979.tb04274.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Migration of the true pacemaker within the sinoatrial cell aggregate in man.

The functional anatomy of the sinoatrial node (SAN) in man is first reviewed, together with its possible anatomical substructure. The true group pacemaker (PM) shift under autonomic drive is then related to a continuous competition between the intrinsic auto-firing period hierarchy and the autonomic topological susceptibility hierarchy. Accordingly, the PM 'skip' to both lower and higher periods following an abrupt and consistent acetylcholine (ACh) release at the SAN periphery, and the PM 'slip' towards a relocation of the next period, as a possible response to a slower and smaller ACh release, are considered. The PM 'skip' and 'slip' as boundaries of the true PM excursion within the SAN during the respiratory cycle, and their statistical properties, are then examined. Under current heart rate control menus in normals, the PM skip appears to follow central influence, whereas the conservative or slipping PMs suggest peripheral control. Finally, interpretation of the PM skip as a salutary sign of functional reserve is proposed, and a method of alleviating the PM skip which confounds electrophysiological testing of the SAN function in patients is devised.

Arrhythmia, Sinus

Atrial arrhythmias in dual chamber pacing and their influence on long-term mortality.

A retrospective study of 252 patients who received a DDD pacemaker between October 1982 and December 1990 was performed. During a mean follow-up of 30 months, reprogramming to the VVI mode was necessary in 39 patients (15.5%). Technical problems causing downgrading occurred 15 times, of which 13 problems became permanent. A total number of 24 patients had sustained atrial arrhythmias, including 14 with atrial fibrillation and 10 with atrial flutter. In this group, conversion to sinus rhythm could be obtained in 38%. After 2 years, reliable DDD pacing was maintained in 86% of the surviving patients. The survival after 1 and 2 years was 94% and 89%, respectively, and was not influenced by arrhythmias or technical problems. We conclude that atrial arrhythmias including flutter are the most important reasons for reprogramming to the VVI mode, although in an important number of patients, predominantly those with flutter, restoration of AV synchrony can be obtained. The high number of patients with atrial flutter could imply some role for DDD devices offering the option of antitachycardia pacing. Reprogramming of the pacing mode did not influence mortality.

Arrhythmia, Sinus

Atrioventricular conduction disturbances in patients with sinoatrial node disease and atrial pacing.

In sinoatrial node disease (SND) atrial pacing may be limited by progression of AV block. The incidence of AV block after AAI systems implantation range, according to various authors, from 0% to 12%. The aim of this study was to examine the AV conduction disturbances that forced a change in the mode of pacing in patients with AAI pacemakers. The information was collected retrospectively from a cohort of 122 patients. The follow-up period ranged from 5 to 83 months (mean = 35). Among these patients there were 37 with sinus bradycardia and 85 with bradycardia-tachycardia syndrome. Their mean age was 63 years. Before AAI pacemaker insertion, all patients had normal AV conduction on 12-lead ECG, and all but five had a Wenckebach cycle length shorter than 500 msec. Seven out of these 122 patients (5.7%) developed symptomatic conduction disturbances (second-degree type I AV block in five, second degree type II AV block in one, and third-degree AV block in one), necessitating a change from AAI to another mode of pacing. We conclude that progression of AV block after atrial pacemaker implantation in patients with SND is infrequent and mild in the majority of cases. Intraventricular disturbances such as left anterior hemiblock represent contraindication to AAI pacing particularly in patients who may be in need of antiarrhythmic drugs.

Arrhythmia, Sinus