PubMed Health⌕ Search

PubMed · 9523762

Study of amorphous alloy structures with medium range atomic ordering.

Abstract

Structures with atomic medium range order (MRO) extending as small as approximately 2 nm in amorphous alloys can be observed under suitable defocus conditions as clear lattice fringe images by means of axial-beam high-resolution electron microscopy (HREM). In this article, our studies of local structure observation in some metal-metalloid amorphous alloys with the "selected-defocus method" are introduced. Also introduced are an HREM image simulation study of amorphous alloy structures and a nano-probe (1-1.5 nm) electron diffraction analysis of MRO structure. A multislice image simulation study for suitable structure models (1) with a random atomic distribution, (2) with MRO regions having different sizes, distributions, and specimen thicknesses, is a necessary step to verify the MRO observation in amorphous alloys. It was demonstrated that not only HREM information but also nano-diffraction information are necessary in order to understand local structures of amorphous alloys.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Hirotsu, T Ohkubo, M Matsushita. 1998-02-15. Study of amorphous alloy structures with medium range atomic ordering.. https://doi.org/10.1002/(sici)1097-0029(19980215)40%3A4%3C284%3A%3Aaid-jemt5%3E3.0.co%3B2-s

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Biological performance of uncoated and octacalcium phosphate-coated Ti6Al4V.

The in vivo behavior of a porous Ti6Al4V material that was produced by a positive replica technique, with and without an octacalcium phosphate (OCP) coating, has been studied both in the back muscle and femur of goats. Macro- and microporous biphasic calcium phosphate (BCP) ceramic, known to be both osteoconductive and able to induce ectopic bone formation, was used for comparison purpose. The three groups of materials (Ti6Al4V, OCP Ti6Al4V and BCP) were implanted transcortically and intramuscularly for 6 and 12 weeks in 10 adult Dutch milk goats in order to study their osteointegration and osteoinductive potential. In femoral defects, both OCP Ti6Al4V and BCP were performing better than the uncoated Ti6Al4V, at both time points. BCP showed a higher bone amount than OCP Ti6Al4V after 6 weeks of implantation, while after 12 weeks, this difference was no longer significant. Ectopic bone formation was found in both OCP Ti6Al4V and BCP implants after 6 and 12 weeks. The quantity of ectopically formed bone was limited as was the amount of animals in which the bone was observed. Ectopic bone formation was not found in uncoated titanium alloy implants, suggesting that the presence of calcium phosphate (CaP) is important for bone induction. This study showed that CaPs in the form of coating on metal implants or in the form of bulk ceramic have a significantly positive effect on the bone healing process.

Alloys↗

Measuring mechanical properties of fine-wire cross-sections used in medical devices.

In this study, it was demonstrated that the nanoindentation technique can be used to measure the elastic modulus and hardness of fine-wire cross-sections with diameters ranging from 100-200 microm. Using miniature optics and a specially developed micrometer positioning system, measurements were successfully performed on the wire cross-sections with an accuracy of 1 microm. Homogeneous wire cross-sections, such as MP35N (high-strength nickel-cobalt alloy), composite wires such as MP35N with a silver core (MP35N/Ag-core), and platinum-clad tantalum (Pt-clad Ta) were studied. From the nanoindentation measurements, the elastic modulus and hardness at different positions and depths were calculated. It was found that both elastic modulus and hardness reached a constant value below the hardened surface, which resulted from mechanical polishing. Material properties obtained from the measurements were compared with the literature values of bulk materials as well as available results on fine wires. The data from the wire cross-sections, especially the uniform material samples, showed that both the elastic modulus and hardness were significantly lower near the outer 10-15 microm of the wire as compared to the rest of the wire, which is due to surface weakening during manufacturing. In addition, both modulus and hardness showed a small but consistent "sawtooth" variation across the diameter of the wires, excluding the outer 10-15 microm, that is postulated to be induced by the distribution of residual stress.

Alloys↗

Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6Al4V substrate.

The corrosion behavior of four different preparations of plasma-sprayed hydroxyapatite (HA) coatings on Ti6Al4V substrates in static Hank's balanced salt solution was investigated using dc potentiodynamic and ac impedance techniques. Two different nominal thicknesses, 50 microm and 200 microm, and two different spraying conditions, were considered. The electrochemical impedance experiments proved this technique to be very suitable for the investigation of the electrochemical behavior of surgical implant alloys when they are coated with HA, which is characterized by the dissolution and passivation characteristics of the underlying metal substrate. Because the coatings are porous, ionic paths between the electrolytic medium and the base material can eventually be produced, resulting in the corrosion of the coated metal. Differences in the corrosion resistance of the coated materials were detected, and a relevant model for the description of the coating degradation in the biosimulating solution was proposed. The model consisted of the description of the coated system in terms of a two-layer model of the surface film. Significant differences in electrochemical behavior for similar nominal thicknesses of HA coatings obtained under different spraying conditions were found.

Alloys↗