PubMed Health⌕ Search

PubMed · 9527836

Temporal-code to rate-code conversion by neuronal phase-locked loops.

Abstract

Peripheral sensory activity follows the temporal structure of input signals. Central sensory processing uses also rate coding, and motor outputs appear to be primarily encoded by rate. I propose here a simple, efficient structure, converting temporal coding to rate coding by neuronal phase-locked loops (PLL). The simplest form of a PLL includes a phase detector (that is, a neuronal-plausible version of an ideal coincidence detector) and a controllable local oscillator that are connected in a negative feedback loop. The phase detector compares the firing times of the local oscillator and the input and provides an output whose firing rate is monotonically related to the time difference. The output rate is fed back to the local oscillator and forces it to phase-lock to the input. Every temporal interval at the input is associated with a specific pair of output rate and time difference values; the higher the output rate, the further the local oscillator is driven from its intrinsic frequency. Sequences of input intervals, which by definition encode input information, are thus represented by sequences of firing rates at the PLL's output. The most plausible implementation of PLL circuits is by thalamocortical loops in which populations of thalamic "relay" neurons function as phase detectors that compare the timings of cortical oscillators and sensory signals. The output in this case is encoded by the thalamic population rate. This article presents and analyzes the algorithmic and the implementation levels of the proposed PLL model and describes the implementation of the PLL model to the primate tactile system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Ahissar. 1998-04-01. Temporal-code to rate-code conversion by neuronal phase-locked loops.. https://doi.org/10.1162/089976698300017683

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Morphologic and functional evaluation of peripheral nerve fibers regenerated through polyimide sieve electrodes over long-term implantation.

We evaluated by morphologic and functional analysis the regeneration of peripheral nerve fibers through polyimide regenerative-type electrodes over long-term implantation. Polyimide sieve electrodes were placed in silicone chambers and implanted between the severed ends of the sciatic nerve in rats. The sieve part had 281 round via holes of 40 microm in diameter, with nine integrated recording-stimulating electrodes arranged around the via holes. The degree of axonal regeneration was examined at 2, 7, and 12 months postimplantation (mpi). Regeneration was successful in 12 of the 13 animals implanted. Reinnervation of distal muscle and nerves increased with time, reaching a plateau about 7 mpi. The number of myelinated fibers increased from 2 to 7 months, at which time it was similar to control values. With time the myelinated fibers matured, with significant increases in axon diameter and myelin thickness. Only 0.6% of the regenerated axons showed evidence of compression near the implanted electrode. The majority of the myelinated fibers that crossed the via holes and had been regenerated through the distal nerve had a normal appearance. Sieve electrodes were useful for nerve stimulation at postimplantation. Stimulation through different active electrodes excited nerve bundles, evoking compound muscle action potentials of varying shape and amplitude, indicative of selective axonal stimulation.

Action Potentials↗

Laryngeal effects of stimulation of rostral and ventral pons in the anaesthetized rat.

In order to study the importance of two pontine regions modulating laryngeal resistance, electrical current or microinjections of glutamate (10-30 nl, 1-3 nmol) were made into the pontine parabrachial complex and the A5 region in spontaneously breathing anaesthetized rats. Two distinct patterns of laryngeal and respiratory responses were elicited. An increase of subglottal pressure was accompanied with an expiratory facilitatory response consisted of a decrease in both respiratory rate and phrenic nerve activity. A decrease of subglottal pressure was accompanied with an inspiratory facilitatory response consisted of an increase in both respiratory rate and phrenic nerve activity. The modification of laryngeal calibre occurred during both respiratory phases in most cases. The concomitant cardiovascular changes of these responses were also analyzed. Controls using guanethidine to block autonomic responses which might interact with respiratory control were also made. Histological analysis of stimulation sites showed a topographical organization of these responses: laryngeal constriction was evoked from Kölliker-Fuse, medial parabrachial nuclei and A5 region, whilst the laryngeal dilation was evoked from the lateral parabrachial nucleus.

Action Potentials↗

EMG discharge patterns during human grip movement are task-dependent and not modulated by muscle contraction modes: a transcranial magnetic stimulation (TMS) study.

Our previous study revealed that, during tonic muscle contraction, remarkable functional differences among intrinsic and extrinsic muscles were observed during two different grip movements, i.e., precision and power grips. To verify whether this evidence is true even under the phasic muscle contraction, magnetic stimulation was delivered over the left scalp while a normal human subject performed phasic precision or power grip responses of the right-hand fingers in a simple reaction time (SRT) paradigm. Magnetic stimulation delivered during the latent period revealed different cortico-motoneuronal excitations between the two grip responses. In particular, the contributions of extensor carpi radialis (ECR) muscle were definitely different between the two grip responses, although motor-evoked potentials (MEPs) of first dorsal interosseous (FDI) prior to, and after EMG onset of movement initiation, were not different. These results were similar to previous results obtained during tonic muscle contraction. Thus, we have concluded that the task-dependent EMG discharge pattern in finger manipulation could not be modulated by muscle contraction modes.

Action Potentials↗