Implementation of a model-based nonuniform scatter correction scheme for SPECT.

Abstract

In this paper four scatter-compensation schemes are considered. The four schemes are all based on a previously developed two-dimensional (2-D) scatter model. Reconstruction is achieved using the iterative expectation-maximization maximum-likelihood (EM-ML) algorithm. The schemes consist of: 1) including the model in both the forward and back projector; 2) just including the model in the forward projector; 3) and 4) implementing the model in a subtraction and addition scheme, respectively. Monte Carlo simulated projection data are used to test the accuracy, convergence properties, and noise properties of the four scatter-compensation schemes. Data are simulated for both uniformly and nonuniformly attenuating objects. The results show that all four correction schemes yield images which are similar in terms of accuracy to that obtained from reconstructing scatter-free data. The subtraction scheme is shown to converge faster than the other compensation schemes, both in terms of iterations and actual time required for reconstruction. The scheme in which the model is only used in the forward-projector and the scatter-addition scheme both performs slightly better, in terms of signal-to-noise ratio (SNR), than the subtraction scheme. However, the forward projector scheme requires significantly more CPU time for reconstruction. The correction scheme in which the scatter model was included in both the forward and backprojectors is shown to produce accurate images with SNR's higher than even a perfect scatter rejection scheme. While the scatter correction scheme with the model in both the forward projector and backprojector has superior noise properties to the other algorithms, the results suggest that the faster subtraction/addition schemes will probably prove most useful for routine clinical scatter compensation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Welch, G T Gullberg. 1997. Implementation of a model-based nonuniform scatter correction scheme for SPECT.. https://doi.org/10.1109/42.650869

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rapid and accurate measurement for phase-change optical recording bits.

Conducting atomic force microscopy (CAFM) and scanning surface potential microscopy (SSPM) have been used to image the phase-change optical recording bits. Commercially available digital versatile discs (DVD) + rewritable (RW) with initialization process were measured in experiments. Comparing the measurement results of both, the measurement resolution of CAFM is far superior to that of SSPM. With the DVD + RW disc rotating at a linear speed of 3.5 m/s, appropriate writing laser power range, may be precisely identified by CAFM as 10-15 mW. This is sufficient to verify the high-resolution recording bits research method. This new method may also be applied to the development of new types of phase-change recording materials.

Image Processing, Computer-Assisted↗

Image analysis by pulse coupled neural networks (PCNN)--a novel approach in granule size characterization.

A biologically inspired spiking neural network model, the pulse coupled neural network (PCNN), has been applied for the first time in bulk particle characterization, and specifically in the characterization of pharmaceutical granule size distributions. The PCNN was trained on surface images of pharmaceutical granule beds, and the adjustable parameters (radius neuron interconnection, r0, linking weight coefficient, beta, local threshold potential, VTheta, and number of iterations) were successfully optimized using design of experiments. As demonstrated with size fractions of granules, it was found that the PCNN produced granule size-dependent signals. In general, a first highest and relatively narrow peak located in the region of two to twelve iterations corresponded to smaller particle size, while larger particles resulted in wider peaks and in highest (not first) peak at a range between 13 and 25 iterations. Better predictions, i.e. lower RMSEP (root mean squared error of prediction) values, were obtained using high beta value, low r0 and VTheta values, while the number of iterations had to exceed 110 and the optimized model (RMSEP lower than 5) corresponded to PCNN variables: r0=1, beta=0.4, VTheta=2, and number of iterations=150. The coefficient of determination (R2) of the model was 0.94 and the predicted variation (Q2) was 0.91, while the Pearson correlation coefficient between the predicted and the measured mean particle size by sieving for eight test batches was 0.98. These findings could be characterized as promising and encouraging for the further use of image analysis by PCNNs in pharmaceutical bulk particle size and shape characterization.

Image Processing, Computer-Assisted↗

Production of siRNA- and cDNA-transfected cell arrays on noncoated chambered coverglass for high-content screening microscopy in living cells.

In this chapter, we provide a protocol for the production of transfected cell arrays in living mammalian cells on noncoated chambered coverglass for the systematic functional analyses of human genes by high-content screening microscopy. This method should facilitate drug target validation by small-interfering RNAs.

Image Processing, Computer-Assisted↗