PubMed · 9536489

The AAPM/RSNA physics tutorial for residents. X-ray interactions.

Abstract

The diagnostic information in a radiograph or fluoroscopic image is largely the result of the quantity of x rays that are not removed from the incident x-ray beam. The information content of the image is delivered by the percentage of noninteracting photons that are successfully recorded. There are four major x-ray interactions: Rayleigh (coherent) scattering. Compton scattering, photoelectric absorption, and pair production. The degree of attenuation and the predominant mechanisms involved in the interactions are influenced by the x-ray energy and tissue composition. In the diagnostic energy range, photoelectric absorption and Compton scattering are the predominant modes of attenuation. One of the challenges in diagnostic imaging is to optimize image acquisition by controlling x-ray attenuation to obtain the appropriate contrast between the tissues while minimizing patient dose and scattered radiation in the image. Imaging techniques such as use of contrast material and dedicated mammography equipment exploit the differences in these types of x-ray interactions to improve the quality and diagnostic utility of the examination. Rayleigh scattering and pair production are presented but do not occur to any significant degree in diagnostic radiography.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J T Bushberg. The AAPM/RSNA physics tutorial for residents. X-ray interactions.. https://doi.org/10.1148/radiographics.18.2.9536489

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Synthesis of FDU-1 silica with narrow pore size distribution and tailorable pore entrance size in the presence of sodium chloride.

Ordered silicas with large (9-15 nm), uniform, cagelike mesopores were synthesized under acidic aqueous conditions from tetraethyl orthosilicate in the presence of sodium chloride using poly(ethylene oxide)-poly(butylene oxide)-poly(ethylene oxide) triblock copolymer B50-6600 (EO39BO47EO39, Dow Chemicals) as a supramolecular template. Except for the use of NaCl in our case, the synthesis mixture composition was the same as that originally reported by Zhao et al. for the synthesis of FDU-1 silica, which was later shown to exhibit a cubic close-packed (Fm3m) structure with stacking faults related to the occurrence of hexagonal close-packed stacking sequences. The copolymer-templated silicas were formed at room temperature and in most cases were subjected to the hydrothermal treatment at 373 or 393 K. The calcined materials were characterized using small-angle X-ray scattering (SAXS) and nitrogen and argon adsorption at 77 K. SAXS patterns were generally similar to those reported for FDU-1 silica, indicating the cubic close-packed (Fm3m) structure, but the presence of stacking faults characteristic of a hexagonal close-packed structure cannot be precluded. The addition of the salt was found to significantly narrow the pore size distributions and to improve the uniformity of entrances to the cagelike mesopores, whereas the pore diameter, specific surface area, and pore volume were similar (in most cases slightly lower) to those for FDU-1 silicas obtained in the absence of NaCl. The materials synthesized in the presence of NaCl also appeared to have better resolved SAXS patterns. The feasibility of tailoring the pore cage diameter (from approximately 9.5 to 14.5 nm) and pore entrance diameter (from below 4 to approximately 8 nm) simply by adjusting the hydrothermal treatment temperature and time was demonstrated, indicating that these simple and convenient ways of structural design of cagelike mesopores are operative in the case of syntheses in the presence of inorganic salts.

Scattering, Radiation↗

Quasi-monochromatic x-rays for diagnostic radiology.

Monochromatic x-ray beams are desirable in various fields of diagnostic radiology; in fact a reduction of the dose and an enhancement of the contrast could be achieved. In this work two different methods to monochromatize x-ray beams produced by conventional tubes have been compared. In the first one the beam is obtained via Bragg diffraction on mosaic crystal and in the second one by attenuating the polychromatic beam with aluminium filters. We have simulated quasi-monochromatic x-ray spectra by setting suitable values of Bragg's angle to obtain beams tuned to 20, 30, 40 and 50 keV with the SHADOW code, an x-ray tracing program designed to study the propagation and the interaction of a photon beam through an optical system. We have validated such a program by comparing some calculated data with measurements carried out on an experimental apparatus. Attenuated polychromatic x-ray spectra have been simulated by setting appropriate values of aluminium filters and potential with the SPECTRUM PROCESSOR, the software version of the Catalogue of Spectral Data for Diagnostic X-Rays, which provides radiographic x-ray spectra that can be attenuated with several material filters. The relation between the energy resolution and the flux as a function of the mean energy has been investigated and results have been compared. Results show that quasi-monochromatic x-ray beams produced via Bragg diffraction exhibit, for a given mean energy and energy resolution, a higher total flux compared to attenuated spectra.

Scattering, Radiation↗

Measurement of scatter factors for 4, 6, 10, and 23 MV x rays at scattering angles between 30 degrees and 135 degrees.

NCRP Report No. 49, published in 1976, describes how to calculate the shielding for the medical use of x rays and gamma rays for energies up to 10 MV, including primary, scattered, and leakage radiation. However, in that report, data for scattered radiation for linear accelerators exist only for 6 MV, and leakage radiation is assumed, incorrectly, to be equivalent to primary radiation. Since the publication of that report, linear accelerators with energies up to 25 MV have been widely used in the radiation therapy community. Thus, there is a need to measure additional data for all energies in the range 4-25 MV. In this study, measurements were made of the "a" factor for 4, 6, 10, and 23 MV x rays at scattering angles between 30 degrees and 135 degrees. The results show that the 6 and 10 MV "a" factor data are consistent with published data, and the 23 MV data are also consistent with recently published data at 18 and 25 MV. The data show that, in general, the "a" factor decreases with energy; the exception is that 23 MV data show a sharp increase at low scattering angles, much greater than at other energies.

Scattering, Radiation↗