PubMed Health⌕ Search

PubMed · 9540646

Predictable exodontia in general practice.

Abstract

Exodontia that is carefully and skillfully done by general dentists is a valuable service to patients. The majority of patients would rather have their family dentist perform necessary extractions or other minor surgery procedures than be referred outside the office. Most teeth that need to be extracted could be removed by a generalist if that person has developed the expertise to do not only relatively easy extractions, but also that percentage that is inevitably more difficult--requiring "surgical" removal. To be successful with exodontia, the dentist must have the ability to select cases within his or her level of comfort and ability, have a working knowledge of sound surgical principles, be able to apply a variety of patient management techniques, and then be prepared to handle whatever complications may arise. This article has presented ideas that should be integrated into the operator's own systematic approach to extractions. It is one of many resources to help the general dentist provide a higher level of surgical treatment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K R Koerner. 1995. Predictable exodontia in general practice.. https://pubmed.ncbi.nlm.nih.gov/9540646/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Failure of ProFile instruments used with high and low torque motors.

AIM: The purpose of this study was to evaluate the failure incidence of ProFile nickel-titanium rotary instruments when used in conjunction with different motors and a specific instrumentation technique. METHODOLOGY: ProFile Ni-Ti rotary instruments (PRI) with 0.06 taper were used in a crown-down technique. In groups 1, 2 and 3, an air, a high torque and a low torque motor were used, respectively. Each group included 30 canals in extracted human molars. One set of PRI sizes 40-15 was used for each canal; they were sterilized before each case. A 2.5% NaOCl solution was used as an irrigant. The number of deformed and separated instruments was recorded for the various experimental groups. RESULTS: Instrument separation did not occur in any of the three groups. One and two instruments were deformed when using the air and high torque motors, respectively. CONCLUSIONS: The results indicated no difference between the three motors with respect to the incidence of instrument failure. The results suggest that the use of PRI in a crown-down manner with air control motors was safe.

Dental High-Speed Equipment↗

A pilot study of measurement of the frequency of sounds emitted by high-speed dental air turbines.

Since the development and use of the high-speed dental air turbine some 45 years ago, concern has been expressed in the literature about a possible cause and effect relationship between use of the drill and hearing loss in dentists. The hearing threshold in humans varies with the frequency of sound. It is well known that dentists experience gradual hearing loss during their working life. The aim of this study was to measure the frequency of sounds emitted by high-speed dental air turbines under different working conditions. Five high-speed dental air turbines were used (2 x Trend TC-80 BC W&H Dentalwerk, Austria, 2 x Black Pearl Eco Bien-air, Switzerland, 1 x Trend TC-80 BC W&H Dentalwerk, Austria. Each turbine was tested under 8 different working conditions: under free working conditions the turbines were tested without burs, with fissure burs, with flare burs, with round burs and with inverted cone burs; under operation they were tested with fissure burs by application to a 3 x 3 x 10 mm amalgam block surface, a 3 x 3 x 10 mm composite block surface, and the occlusal surface of an extracted molar tooth. Forty sound recordings were made in total using a computer with a microphone (Shure 16 LC) located 30 cm away from the samples, at 10-s intervals using a mixer. Frequency analysis was done by a Cool Edit Pro 1.2 computer program. Data were analyzed by multi-variate analysis with the S.P.S.S 9.05 software program. The average measurement was 6860 Hz. According to the statistical analysis there was no significant difference in the frequencies recorded under different working conditions. There was also no significant difference among the different high-speed dental air turbines at alpha = 0,05, P > alpha /2 levels. These results indicate that under any working conditions, high-speed dental air turbines emit frequencies which can cause hearing loss.

Dental High-Speed Equipment↗