PubMed · 9547498

A new approach to electron-beam reference dosimetry.

Abstract

A new approach is proposed for electron-beam dosimetry under reference conditions and data necessary to use this approach are presented. The approach has the following features; it uses ion chambers and starts from an absorbed-dose calibration factor for 60Co to be consistent with the present proposal for the new AAPM photon-beam protocol; it uses R50 to specify the beam quality and the reference depth, dref = 0.6R50 - 0.1 (all quantities in cm), recommended by Burns et al. [Med. Phys. 23, 383-388 (1996)]; it has a formalism which is parallel to the kQ formalism for photon-beam dosimetry; it fully accounts for the impact on stopping-power ratios of realistic electron beams; it allows an easy transition to using primary standards for absorbed dose to water in electron beams when these are available. The equation for dose to water under reference conditions is; DWQ = MPionPgrQk'R50kecalND,w60Co. The term PgrQ is not needed with plane-parallel chambers but corrects for gradient effects with cylindrical chambers and is measured in the user's beam. The parameter kecal is associated with converting the 60Co absorbed-dose calibration factor into one for an electron beam of quality Qe and contains most of the chamber to chamber variation. Calculated values of kecal are presented as well as Monte Carlo calculated Pwall values for plane-parallel chambers in a water phantom irradiated by a 60Co beam since these are needed to calculate kecal. The factor k'R50 is a function of R50 and converts the absorbed-dose calibration factor to that for the electron-beam quality of interest. Two analytical expressions are presented which are close to universal expressions for all cylindrical Farmer-like chambers and for well-guarded plane-parallel chambers respectively. Calculated values are presented graphically for electron beams with energies between 5 and 50 MeV.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D W Rogers. 1998. A new approach to electron-beam reference dosimetry.. https://doi.org/10.1118/1.598211

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fermentation process tracking through enhanced spectral calibration modeling.

The FDA process analytical technology (PAT) initiative will materialize in a significant increase in the number of installations of spectroscopic instrumentation. However, to attain the greatest benefit from the data generated, there is a need for calibration procedures that extract the maximum information content. For example, in fermentation processes, the interpretation of the resulting spectra is challenging as a consequence of the large number of wavelengths recorded, the underlying correlation structure that is evident between the wavelengths and the impact of the measurement environment. Approaches to the development of calibration models have been based on the application of partial least squares (PLS) either to the full spectral signature or to a subset of wavelengths. This paper presents a new approach to calibration modeling that combines a wavelength selection procedure, spectral window selection (SWS), where windows of wavelengths are automatically selected which are subsequently used as the basis of the calibration model. However, due to the non-uniqueness of the windows selected when the algorithm is executed repeatedly, multiple models are constructed and these are then combined using stacking thereby increasing the robustness of the final calibration model. The methodology is applied to data generated during the monitoring of broth concentrations in an industrial fermentation process from on-line near-infrared (NIR) and mid-infrared (MIR) spectrometers. It is shown that the proposed calibration modeling procedure outperforms traditional calibration procedures, as well as enabling the identification of the critical regions of the spectra with regard to the fermentation process.

Calibration↗

Particle sizing with a fast polar nephelometer.

We reported previously the design of a polar nephelometer that uses a rotational confocal imaging setup to enable fast scanning of the scattering phase function within a field of view of 55 degrees . The full dynamic range of the detection system can be used by increasing the signal-to-noise ratio by means of averaging successive scans. The calibration of the angular response of the instrument is achieved by obtaining the transfer function of the optical detection system using Rayleigh scatterers. Accurate particle sizing of individual polystyrene spheres (ranging from 1.5 to 9 micro m in diameter) in aqueous suspension is achieved by maximizing a correlation coefficient between precalculated tables of Mie phase functions and data obtained from the polar nephelometer. Good correlation is achieved between experimental and theoretical data, proving the functioning of the instrument as a fast and convenient particle sizer.

Calibration↗

Online standard additions calibration of transient signals for inductively coupled plasma mass spectrometry.

An online standard additions calibration method for transient signals in ICPMS is demonstrated in which a small volume of standard is injected as a spike into the sample/carrier stream, overlaying the analyte peak. This technique provides the advantages of conventional standard additions but requires only a single sample run. The method corrects for matrix effects and is suitable for transient signals in which the severity of the matrix effect changes over the analyte peak. The method uses a peak-fitting program to determine the area of the underlying peak and is shown to be effective for the determination of trace metal concentrations in both a high ionic strength matrix and in a biological matrix (urine). Eight analytes with concentrations in the range of 0.82-233.2 mug L-1 in urine were simultaneously determined using a standard spiking solution of 75 mug L-1 injected through a 100-muL loop. The measured concentrations for analytes free of spectral interferences agreed with the certified values, and the precision achieved was comparable to that achieved by the certifying agency. Using a conventional cross-flow nebulizer and Scott-type spray chamber, the accuracy obtained for online standard additions calibration was within 2%, and the precision was within 5%.

Calibration↗