PubMed HealthSearch

PubMed · 9552324

Optima: a windows-based program for computer-aided optimization of controlled-release dosage forms.

Abstract

The purpose of this work was to develop a computer program that assists optimization of controlled-release devices, both visually and mathematically, using response surface methodology (RSM). A Windows-based computer program, Optima, which interactively implemented a number of subroutines for the optimization procedure, was developed. Optima is an integrated, user-friendly, and graphically oriented program for pharmaceutical dosage form optimization. Central composite design is implemented in the program. First- and second-order models containing up to five variables can be fitted to the data. The user can also choose between linear and exponential individual desirability functions, and use them to construct an overall desirability function that combines all the response variables in a single response. The program can predict the optimum levels of experimental variables, with respect to individual responses and/or the overall desirability. Optima has been successfully used in the development of sustained-release AZT-loaded microspheres. During the optimization process, three experimental variables were investigated and four responses were measured. The experimental design was a central composite design that was generated by the program. The response values were used by the program to calculate the individual desirability functions, which were then combined into an overall desirability function. The individual responses as well as the overall desirability function were optimized by fitting to a second-order polynomial equation. The response surfaces were generated and optimum levels of the experimental variables were predicted. The observed responses of the optimized formulation were very close to those predicted by Optima. The program proved to be a very useful, integrated tool for optimization of the controlled-release microspheres.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D R Lu, K Abu-Izza, W Chen. 1996. Optima: a windows-based program for computer-aided optimization of controlled-release dosage forms.. https://doi.org/10.3109/10837459609031435

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A methodology for simulating biological systems using Microsoft Excel.

The objective of this present study was to develop a simple, easily understood methodology for solving biologically based models using a Microsoft Excel spreadsheet. The method involves the use of in-cell formulas in which Rows and Columns of new data are generated from data typed into the spreadsheet, but does not require any programming skills or use of the macro language. The approach involves entering the key parameter values into the spreadsheet and conducting the simulation by solving a set of equations based on these parameter values. The examples used in this paper are firstly, a simple voltage clamp simulation in which initial parameter values are used to calculate a system in steady state. The second example is a current clamp simulation where steady state is not reached and the solution of the equations for each time increment is used as the input for the next time increment in the simulation. The calculations are based on the Hodgkin Huxley mathematical equations that describe the voltage dependence of ion channel behavior. The problems and flexibility of the method are briefly discussed. The methodology developed in this present study should help novice modelers to create simple simulations without the need to learn a programming language or purchase expensive software.

Computer Graphics

[Optimization of numerical measurement parameters for ECG-triggered MRI snapshot-FLASH myocardial perfusion studies].

BACKGROUND AND AIMS: In MR examinations of myocardial perfusion by the use of Snapshot-FLASH sequences it is of major importance that the achievable signal difference between pre- and normal postcontrast myocardium be maximized. METHODS: In ECG-triggered Snapshot-FLASH sequences the signal intensity of the myocardium depends on the flip angle alpha, the inversion time TI and the trigger delay TD (both depending on the cardiac frequency f) for unchanged slice thickness (SL), matrix size (MA), repetition time (TR) and echo time (TE). Therefore a simulation of the signal behavior of pre- and postcontrast myocardium based on Bloch's equations was performed by varying the flip angle alpha, TI and TD for different cardiac frequencies in order to determine an optimized combination of the measurement parameters. RESULTS: In normal heart rates (50-70 beats/min) maximal signal differences between pre- and normal postcontrast myocardium can be reached for inversion times TI = 170-200 ms and a flip angle alpha = 11 degrees. For higher heart rates again alpha = 11 degrees and TI = 200-220 ms with shortened TD (TD = 0 for f > 90 beats/min) were found to be optimal. The calculated values were semiquantitatively confirmed in phantom and volunteer measurements. CONCLUSIONS: The described method allows cardiac frequency dependent optimization of the Snapshot-FLASH measurement parameters alpha, TI and TD in order to reach a maximum in signal contrast between normal and malperfused myocardium.

Computer Graphics

Neurosurgical simulation and navigation with three-dimensional computer graphics.

We developed a pre-operative simulation and intra-operative navigation system with three-dimensional computer graphics (3D-CG). Because the 3D-CG created by the present system enables visualization of lesions via semitransparent imaging of the scalp surface and brain, the expected operative field could be visualized on the computer display pre-operatively. We used two different configurative navigators. One is assembled by an arciform arm and a laser pointer. The arciform arm consists of 3 joints mounted with rotary encoders forming an iso-center system. The distal end of the arm has a laser pointer, which has a CCD for measurement of the distance between the outlet of the laser beam, and the position illuminated by the laser pointer. Using this navigator, surgeons could accurately estimate the trajectory to the target lesion, and the boundaries of the lesion. Because the other navigator has six degrees of freedom and an interchangeable probe shaped like a bayonet on its tip, it can be used in deep structures through narrow openings. Our system proved efficient and yielded an unobstructed view of deep structures during microscopic neurosurgical procedures.

Computer Graphics