PubMed Health⌕ Search

PubMed · 9576313

Dimensional stability of record bases fabricated from light-polymerized composite using two methods.

Abstract

STATEMENT OF PROBLEM: Record bases fabricated from resin-based composite, which undergoes polymerization shrinkage during curing, can distort during curing to produce significant gaps along the posterior border. PURPOSE: This study evaluated the pattern of gap formation that occurs over the palatal area of a maxillary record base fabricated from light-cured composite (Triad), and determined whether changes in the fabrication method affects the size and pattern of gap formation. Effects of composite width and passage of time on gap formation were also analyzed. MATERIAL AND METHODS: Twenty record bases were fabricated with two methods: (1) according to the manufacturer's directions, the entire surface of the record base was exposed to the curing light; and (2) the palatal area of the record base was covered with foil to prevent light penetration, and the base was light cured in three stages with readaptation of the uncured composite between stages. Ten record bases from each group were tested 1 hour after fabrication; the remaining 10 from each group were tested 7 days after fabrication. Measurements of adaptation were made at three points representing the right and left ridge crests and midpalatal areas. The first measurement was taken at the posterior border and subsequent measurements were made at 5 mm increments after reduction of the posterior border of the cast and record base with a model trimmer. RESULTS: Dimensional changes were observed in both procedures. The largest discrepancy occurred at the posterior border of record bases fabricated using method 1. Mean gap formation at the posterior border in this group after 1 hour was 454, 729, and 334 microm and 483, 841, and 330 microm after 7 days at points A, B, and C, respectively. Record bases fabricated with procedure 2 demonstrated mean gap sizes at the posterior border after 1 hour of 219, 421, and 208 microm and 267, 403, and 192 microm after 7 days at points A, B, and C, respectively. No significant influence of composite width on gap size was found. CONCLUSION: The average gap size due to stage curing (method 2) was never greater than the corresponding gap that arose from the use of the manufacturer's recommendations (method 1). Limiting the amount of surface area exposed to the curing light and readapting the uncured composite to the cast between curing episodes can significantly reduce the mean gap size occurring at the posterior border.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K G Boberick, J McCool. 1998. Dimensional stability of record bases fabricated from light-polymerized composite using two methods.. https://doi.org/10.1016/s0022-3913(98)70152-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of the activator in an acrylic bone cement on an array of cement properties.

In all but one of the acrylic bone cement brands used in cemented arthroplasties, N,N-dimethyl-4-toluidine (DMPT) serves as the activator of the polymerization reaction. However, many concerns have been raised about this activator, all related to its toxicity. Thus, various workers have assessed a number of alternative activators, with two examples being N,N-dimethylamino-4-benzyl laurate (DMAL) and N,N-dimethylamino-4-benzyl oleate (DMAO). The results of limited characterization of cements that contain DMAL or DMAO have been reported in the literature. The present work is a comprehensive comparison of cements that contain one of these three activators, in which the values of a large array of their properties were determined. These properties range from the setting time and maximum exotherm temperature of the curing cement to the variation of the loss elastic modulus of the cured cement with frequency of the applied indenting force in dynamic nanoindentation tests. The present results, taken in conjunction with those presented in previous reports by the present authors and co-workers on other properties of these cements, indicate that both DMAL and DMPT are suitable alternatives to DMPT.

Acrylic Resins↗

Dynamic scaling of polymer gels comprising nanoparticles.

We present dynamic light scattering (DLS) measurements of soft poly(methyl-methacrylate) (PMMA) and polyacrylamide (PA) polymer gels prepared with trapped bodies (latex spheres or magnetic nanoparticles). We show that the anomalous diffusivity of the trapped particles can be analyzed in terms of a fractal Gaussian network gel model for the entire time range probed by DLS technique. This model is a generalization of the Rouse model for linear chains extended for structures with power law network connectivity scaling, which includes both percolating and uniform bulk gel limits. For a dilute dispersion of strongly scattering particles trapped in a gel, the scattered electric field correlation function at small wavevector ideally probes self-diffusion of gel portions imprisoning the particles. Our results show that the time-dependent diffusion coefficients calculated from the correlation functions change from a free diffusion regime at short times to an anomalous subdiffusive regime at long times (increasingly arrested displacement). The characteristic time of transition between these regimes depends on scattering vector as approximately q(-2), while the time decay power exponent tends to the value expected for a bulk network at small q. The diffusion curves for all scattering vectors and all samples were scaled to a single master curve.

Acrylic Resins↗