Volume delivery during high frequency oscillation.

Abstract

AIM: To examine the delivered volume during "high volume strategy" high frequency oscillation, used as rescue treatment in preterm infants; and to identify factors, other than frequency and oscillatory amplitude, influencing the magnitude of volume delivery. METHOD: Twenty infants (median gestational age 29 weeks) were studied on 45 occasions. Two oscillator types were used (SensorMedics and SLE). Delivered volume was measured under clinical conditions with the arterial blood gases within a predetermined range. A specially calibrated pneumotachograph system was used. RESULTS: Overall, the median delivered volume was 2.4 ml/kg (range 1.0 to 3.6 ml/kg); on 32 occasions the delivered volume was greater than 2.0 ml/kg and on seven greater than 3.0 ml/kg. The delivered volume related significantly to disease severity; there was an inverse correlaton between delivered volume and both the oxygenation index (OI) (r = -0.51) and AaDO2 (r = -0.54). CONCLUSION: Delivered volume during HFO may, in certain infants, exceed the anatomical dead space, permitting some direct alveolar ventilation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Dimitriou, A Greenough, V Kavvadia, B Laubscher, A D Milner. 1998. Volume delivery during high frequency oscillation.. https://doi.org/10.1136/fn.78.2.f148

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sequential meta-analysis of past clinical trials to determine the use of a new trial.

BACKGROUND: Clinical trials can be stopped early based on interim analyses or sequential analyses. In principle, sequential analyses can also be used to decide whether enough evidence has been gathered in completed trials to make further trials unnecessary. We demonstrate such an application through a retrospective analysis of clinical trials comparing ventilation methods for the treatment of preterm newborns. METHODS: We identified 5 recent trials that compared high-frequency ventilation with conventional mechanical ventilation in the treatment of preterm newborns. Death or chronic lung disease and chronic lung disease in survivors were the primary clinical outcomes of interest. We applied sequential meta-analyses to these 5 studies. RESULTS: After including the first study of the last 5 trials in a sequential meta-analysis, the boundary of "no clinically relevant effect" was crossed for both outcomes (death or chronic lung disease). A sensitivity analysis using a reduction in the size of assumed clinically relevant effect showed the same findings after 2 trials. CONCLUSIONS: Sequential meta-analyses showed that a lack of clinically relevant effect had been established after the first of the 5 trials. If such an analysis had been conducted after the first or second of these clinical trials, it might have led to changes in the study design of subsequent trials or even to a reassessment of the need for further trials.

High-Frequency Ventilation↗