A 'fail-safe' screening programme for diabetic retinopathy.

Abstract

OBJECTIVE: To improve screening for diabetic retinopathy in a hospital diabetic clinic through the use of the audit process. DESIGN: Comparison of an existing system of screening for diabetic retinopathy (a specialist optometrist using ophthalmoscopy alone) with a new system in which a specialist optometrist examined retinal Polaroid photographs taken through pharmacologically dilated pupils and combined this with ophthalmoscopy in all cases except when the photographs were perfect and definitely showed no retinopathy. In this new system, the optometrist could discuss cases of uncertainty with a diabetes physician while the patient was still in the clinic with eyes dilated. SETTING: Inner city hospital diabetes clinic. SUBJECTS: 289 hospital diabetic clinic patients not already attending an ophthalmologist; a consecutive series of 144 such patients for the first audit, 145 for the repeat audit. MAIN OUTCOME MEASURES: Assessment of each screening system against a gold standard. For the first audit this was agreement by two of four diabetes physicians, who combined examination of the photographs with the findings from dilated ophthalmoscopy, on the classification of the retinae of each patient, guided by standard European criteria. For the second audit, the gold standard was enhanced by discussing the photographs and findings of all patients with an independent ophthalmologist. For patients requiring referral, a second ophthalmologist also commented on the case. RESULTS: The addition of retinal photography to universal pupil dilatation, and the availability of diabetes physician backup to discuss cases of uncertainty, greatly increased the optometrists' detection rate. Sensitivities for the first (ophthalmoscopy only) and second (ophthalmoscopy plus photography plus diabetologist back-up) audits were, respectively, 71.4% vs 100% for sight-threatening retinopathy, 33% vs 100% for retinopathy requiring six-month review, and 40.3% vs 97.2% for any retinopathy (p = 0.002). CONCLUSIONS: Optometrists specialising in diabetic retinopathy using Polaroid retinal photography and ophthalmoscopy, both through dilated pupils, backed up by experienced diabetologists to discuss cases of uncertainty, could form the basis of a retinopathy screening service that accurately identifies and categorises retinopathy and does not miss sight-threatening cases.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R E Ryder, C F Close, A J Krentz, M D Gray, H Souten, K G Taylor, J M Gibson, E E Kritzinger. A 'fail-safe' screening programme for diabetic retinopathy.. https://pubmed.ncbi.nlm.nih.gov/9597629/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Relationship between optical coherence tomography-measured central retinal thickness and visual acuity in diabetic macular edema.

OBJECTIVE: To compare optical coherence tomography (OCT)-measured retinal thickness and visual acuity in eyes with diabetic macular edema (DME) both before and after macular laser photocoagulation. DESIGN: Cross-sectional and longitudinal study. PARTICIPANTS: Two hundred ten patients (251 eyes) with DME enrolled in a randomized clinical trial of laser techniques. METHODS: Retinal thickness was measured with OCT and visual acuity was measured with the electronic Early Treatment of Diabetic Retinopathy procedure. MAIN OUTCOME MEASURES: Optical coherence tomography-measured center point thickness and visual acuity. RESULTS: The correlation coefficients for visual acuity versus OCT center point thickness were 0.52 at baseline and 0.49, 0.36, and 0.38 at 3.5, 8, and 12 months after laser photocoagulation. The slope of the best fit line to the baseline data was approximately 4.4 letters (95% confidence interval, 3.5-5.3) of better of visual acuity for every 100-mum decrease in center point thickness at baseline with no important difference at follow-up visits. Approximately one third of the variation in visual acuity could be predicted by a linear regression model that incorporated OCT center point thickness, age, hemoglobin A1C, and severity of fluorescein leakage. The correlation between change in visual acuity and change in OCT center point thickening 3.5 months after laser treatment was 0.44, with no important difference at the other follow-up times. A subset of eyes showed paradoxical improvements in visual acuity with increased center point thickening (7%-17% at the 3 time points) or paradoxical worsening of visual acuity with a decrease in center point thickening (18%-26% at the 3 time points). CONCLUSIONS: There is modest correlation between OCT-measured center point thickness and visual acuity, and modest correlation of changes in retinal thickening and visual acuity after focal laser treatment for DME. However, a wide range of visual acuity may be observed for a given degree of retinal edema. Thus, although OCT measurements of retinal thickness represent an important tool in clinical evaluation, they cannot substitute reliably as a surrogate for visual acuity at a given point in time. This study does not address whether short-term changes on OCT are predictive of long-term effects on visual acuity.

Diabetic Retinopathy↗

Identification of ganglion cell neurites in human subretinal and epiretinal membranes.

AIM: To determine whether neural elements are present in subretinal and epiretinal proliferative vitreoretinopathy (PVR) membranes as well as in diabetic, fibrovascular membranes removed from patients during vitrectomy surgery. METHODS: Human subretinal and epiretinal membranes of varying durations were immunolabelled with different combinations of antibodies to glial fibrillary acidic protein, vimentin, neurofilament protein and laminin. RESULTS: Anti-neurofilament-labelled neurites from presumptive ganglion cells were frequently found in epiretinal membranes and occasionally found in subretinal membranes. In addition, the neurites were only observed in regions that also contained glial processes. CONCLUSIONS: These data demonstrate that neuronal processes are commonly found in human peri-retinal cellular membranes similar to that demonstrated in animal models. These data also suggest that glial cells growing out of the neural retina form a permissive substrate for neurite growth and thus may hold clues to factors that support this growth.

Diabetic Retinopathy↗

Capillary electrophoretic assay for nitrate levels in the vitreous of proliferative diabetic retinopathy.

The determination of nitric oxide (NO) in human vitreous samples is complicated by the relatively short half-life of the analyte and the viscous, high salt and protein biological matrix. In this work, we developed a fast (<5min) and useful CE method to determine the stable metabolite, nitrate, from vitreous samples. This proposed method has been successfully applied to determine the nitrate levels from the vitreous humor of patients undergoing vitrectomy for a variety of conditions. A statistically significant increase (P=0.000001) of the mean level of nitrate was observed in vitreous humor of patients with proliferative diabetic retinopathy (41.17+/-4.09microM, n=27) versus controls (15.22+/-0.86microM, n=35). The elevated levels of nitrate in the vitreous of patients known to have diabetic retinopathy suggests that NO is involved with the pathology of this disease.

Diabetic Retinopathy↗