PubMed Health⌕ Search

PubMed · 9603042

An elbow joint movement control model with visual feedback.

Abstract

A motor program generator control model is proposed to simulate neuromuscular control. Three muscles (Biceps, Triceps, Brachialis) driving elbow joint flexion in a plane are simulated by integrating their nonlinear dynamic property and spinal neural circuitry. The motor descending commands are described by a visual feedback signal from the joint and an excitation signal for the motor neuron pool. The visual feedback signal mimics the gamma command whereas the excitation signal mimics another descending co-activation command. The gamma command is expressed as the output of a PID controller with the visual feedback error signal as the input. The gamma command and the motoneuron pool background activity are the inputs to the motoneuron pool model coupled with the Renshaw cell recurrent inhibitions. The output of the motoneuron pool model mimics the alpha command feeding directly to the muscle dynamics. A movement is produced by reducing the error signal between goal position and actual position and altering excitation signal properly. The simulation results show that a burst pattern of excitation signal and a PID controller can accurately trace the terminal goal and generate a smooth movement with a bell shaped velocity profile. The muscle activation signals have the characteristic similar to the smoothed EMG. Changing different parameters of the PID can cause the same effects as the stimulus pulse intensity or duration modulation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Xiao, X Li. 1997. An elbow joint movement control model with visual feedback.. https://pubmed.ncbi.nlm.nih.gov/9603042/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrasound of the elbow.

The elbow is an important synovial hinge joint of the upper extremity. This joint represents a common site of musculoskeletal symptomatology, affecting all age groups. The advantages of ultrasound imaging of the elbow include easy availability, multiplanar capability and the ability to assess structures dynamically. Patient symptomatology and site of maximal tenderness can be directly correlated with imaging findings. Comparison is easily made with the contralateral side. Particular strengths include the ability to assess para-articular structures, such as regional tendons and ligaments, in addition to assessment of joint effusions, loose bodies and regional bursae. With operator experience and excellent technique, ultrasound is a valuable imaging tool for assessment of disorders of the elbow joint.

Elbow Joint↗

The ultrasonographic and electrodiagnostic findings of ulnar neuropathy at the elbow.

OBJECTIVE: To evaluate and compare the morphologic changes of the ulnar nerve at the elbow, using ultrasonography, between patients with cubital tunnel syndrome and retrocondylar compression syndrome determined with electrodiagnosis. DESIGN: Prospective study using electrodiagnosis and ultrasonography. SETTING: An outpatient rehabilitation clinic in a tertiary university hospital in South Korea. PARTICIPANTS: Thirteen patients (8 men, 5 women; mean age, 48.2y). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: In the electrodiagnostic study, we used the inching technique to localize the ulnar nerve lesion at the elbow. In the ultrasonography study, we measured the length of the swollen ulnar nerve and the ratio of the nerve diameter between the proximal end of the medial epicondyle to the elbow joint level and the tip of medial epicondyle to the elbow joint level. RESULTS: The mean length of the swollen ulnar nerve segment in retrocondylar compression syndrome (2.58+/-0.58cm) was significantly longer than that of cubital tunnel syndrome (1.64+/-0.31cm). The mean ratio of the nerve diameter between the proximal end of medial epicondyle and the elbow joint level was significantly larger in retrocondylar compression syndrome (1.52+/-0.25) than that of cubital tunnel syndrome (1.06+/-0.06). CONCLUSIONS: Ultrasonography detected the morphologic changes and the extent of the ulnar nerve lesion at the elbow, and it can become a screening and follow-up imaging modality in patients with ulnar neuropathy at the elbow.

Elbow Joint↗

[Humeroradial plica: frequency and visualization on MRI].

PURPOSE: To determine frequency and size of a humeroradial plica and correlate it with degenerative changes, and to determine frequency of the visualization of a synovial fold on MR-Images (T1-weighted spin-echo and STIR sequences) and correlate it with degenerative changes. MATERIALS AND METHODS: Forty-two elbow specimens were dissected and studied for humeroradial synovial folds (small, medium, large) and degenerative changes (absent, medium, strong), and 88 elbow MR-images were analyzed for a synovial fold (not visible, small, large) and degenerative changes (absent, medium, strong). Comparison was performed using the chi (2) test. RESULTS: Dissections revealed a synovial fold in all cases. The sizes were small in n = 13 (31 %), medium in n = 24 (57 %), and large in n = 5 (12 %). Degenerative changes were absent in n = 9 (21.4 %), medium in n = 29 (69 %), and strong in n = 4 (9.6 %). On MRI the synovial fold was not visible in n = 67 (76 %), small in n = 12 (14 %), and large in n = 9 (10 %). Degenerative changes on MRI were absent in n = 65 (74 %), medium in n = 15 (17 %), and strong in n = 8 (9 %). The size of the fold correlated positively with degenerative changes in the specimen but not with degenerative changes on MRI. The T1-SE sequence was superior to the STIR sequence in revealing the synovial fold. DISCUSSION: A humeroradial plica is a regular finding, but visualized by MRI in only approximately 20 %, probably due to its variable size. Its visualization succeeds best with T1-spin-echo sequences.

Elbow Joint↗